European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society
-
To compare the residual range of motion (ROM) of cortical screw (CS) versus pedicle screw (PS) instrumented lumbar segments and the additional effect of transforaminal interbody fusion (TLIF) and cross-link (CL) augmentation. ⋯ Similar residual motion is found with CS and PS instrumentation, except of slightly, but significantly inferior reduction of ROM in LB with CS. Differences between CS and PS in diminish with TLIF but not with CL augmentation.
-
This study aimed to establish biomarkers to predict the progression of ossification by examining ossification volume and bone metabolism dynamics in patients with ossification of the posterior longitudinal ligament (OPLL). ⋯ Younger age, hypophosphatemia, and high serum sclerostin are risk factors for OPLL progression. Serum phosphorus and sclerostin could serve as important biomarkers for predicting ossification progression.
-
Preoperative curve assessment is important in adolescent idiopathic scoliosis (AIS). Our objective is to clarify the role of side-bending radiographs (SBR) and fulcrum-bending radiographs (FBR) in predicting postoperative Cobb angle in nonstructural and structural curves. ⋯ FBR is predictive of postoperative correction angle of the structural curve, whereas SBR is predictive of postoperative correction angle of the nonstructural curve.
-
To elucidate residual motion of cortical screw (CS) and pedicle screw (PS) constructs with unilateral posterior lumbar interbody fusion (ul-PLIF), bilateral PLIF (bl-PLIF), facet-sparing transforaminal lumbar interbody fusion (fs-TLIF), and facet-resecting TLIF (fr-TLIF). ⋯ bl-PLIF and TLIF show similarly low residual motion in both PS and CS constructs, but ul-PLIF results in increased motion. The fs-TLIF technique is able to further decrease motion compared to fr-TLIF in both the CS and PS constructs.
-
To evaluate the motion-preserving properties of vertebral body tethering with varying cord/screw constructs and cord thicknesses in cadaveric thoracolumbar spines. ⋯ The present biomechanical study found similar motion for 4.0-5.0 mm single-cord constructs and the least motion for double-cord constructs in the thoracic and lumbar spine suggesting that larger diameter 5.0 mm cords may be a more promising motion-preserving option, due to their increased durability compared to smaller cords. Future clinical studies are necessary to determine the impact of these findings on patient outcomes.