The study design includes prospective evaluation of percutaneous osteosynthesis associated with cement kyphoplasty on 18 patients. The objective of the study is to assess the efficacy of a percutaneous method of treating burst vertebral fractures in patients without neurological deficits. Even if burst fractures are frequent, no therapeutic agreement is available at the moment. ⋯ Minimally invasive methods of treating burst vertebral fractures can be performed via the percutaneous pathway. This approach gives similar vertebral height recovery and kyphosis correction rates to those obtained with open surgery. It provides a short hospital stay, however, and might therefore constitute a useful alternative to open surgical methods.
-
The study design described here is a posterior C1-C2 fusion technique composed of bilateral C1 hooks and C2 pedicle screws. In addition, the clinical results of using this method on 13 patients with C1-C2 instability are reported. The objectives are to introduce a new technique for posterior C1-C2 fusion and to evaluate the clinical outcome of using it to treat C1-C2 instability. ⋯ Bony fusion and construction stability were observed in all 13 patients (100%) on their follow-up radiographs, and no instrument failure was observed. Bilateral C1 hooks combined with C2 pedicle screws can be used as an alternative treatment method for C1-C2 dislocation, especially in cases not suitable for the use of transarticular screws. The clinical follow-up shows that this technique is a safe and effective method of treatment.
-
Promising strategies are being developed to replace or regenerate the herniated nucleus pulposus. However, clinical efficacy of these methods has still to be addressed, and the lack of appropriate annulus closure techniques is increasingly being recognised as a major limiting factor. In the current study, in vitro and in vivo evaluation of novel annulus closure devices (ACDs) was performed. ⋯ Moreover, two endplate reactions extending into the subchondral bone were observed, most likely due to continuous friction between the ACD and the vertebrae. Although current results are encouraging first steps towards the development of an efficient ACD for animal models, further optimisation is necessary. Current results also show that one cannot rely on in vitro biomechanical studies with annulus closure techniques, and these should always be confirmed in vivo in a large animal model.
-
Nonsurgical treatment of Jefferson burst fractures (JBF) confers increased rates of C1-2 malunion with potential for cranial settling and neurologic sequels. Hence, fusion C1-2 was recognized as the superior treatment for displaced JBF, but sacrifies C1-2 motion. Ruf et al. introduced the C1-ring osteosynthesis (C1-RO). ⋯ Simultaneous compressive forces on the C1-lateral masses and occipital condyles allow for the recreation of the functional C0-2 ligamentous tension band and height. We demonstrated that under physiological loads, the C1-RO restores sufficient stability at C1-2 preventing significant translation. C1-RO might be a valid alternative for the treatment of displaced JBF in comparison to fusion of C1-2.