European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society
-
Atlantoaxial (C1-C2) facet joint osteoarthitis is a distinct clinical syndrome that often goes unrecognized. Severe pain resistant to conservative treatment that is corroborated by the radiographic findings represents the indication for surgery. The aim of this study was to retrospectively examine the long-term outcome [after an average 6.5 years (SD 4.0)] of C1-2 fusion for osteoarthritis of the atlantoaxial segment in 35 consecutive patients [25 male, 10 female; aged 62 (SD 15) years]. ⋯ The average score on the NPDS (0-100) was 34 (SD 27), representing 'mild' neck problems, and the average pain intensity (0-5 VAS) was 1.5 (SD 1.5). Eighty-five percent of the patients declared that they would make the same decision again to undergo surgery. In conclusion, in a group of patients with a painful and debilitating degenerative disorder of C1-2, posterior transarticular atlantoaxial fusion proved to be an effective treatment with a low rate of serious complications.
-
Randomized Controlled Trial Comparative Study
A prospective randomized study comparing a cervical carbon fiber cage to the Smith-Robinson technique with allograft and plating: up to 24 months follow-up.
Intervertebral carbon fiber cages may reduce graft collapse and promote bony fusion. Their safety and efficacy in the cervical spine have been investigated; however, no study has compared the outcomes of anterior cervical decompression and placement of a carbon fiber cage with placement of allograft and plate. ⋯ The outcomes after cervical decompression and placement of a carbon fiber cage appear to be similar to cervical decompression with allograft and plating by the Smith-Robinson technique.
-
Polyetheretherketone (PEEK) is a novel polymer with potential advantages for its use in demanding orthopaedic applications (e.g. intervertebral cages). However, the influence of a physiological environment on the mechanical stability of PEEK has not been reported. Furthermore, the suitability of the polymer for use in highly stressed spinal implants such as intervertebral cages has not been investigated. ⋯ The stress and strain maxima in the implants were well below the material strength limits of PEEK. In summary, the experimental results verified the mechanical stability of the PEEK-OPTIMA polymer in a simulated physiological environment, and over extended loading periods. Finite element analysis supported the use of PEEK-OPTIMA for load-bearing intervertebral implants.
-
A retrospective clinical-radiological study to evaluate the long-term outcome after artificial disc replacement was performed. The objective is to investigate long-term results after implantation of a modular type artificial disc prosthesis in patients with degenerative disc disease (DDD). Total disc replacement (TDR) is a surgical procedure intended to save segmental spinal function, and thus replace spondylodesis. ⋯ Although no adjacent segment degeneration was observed in the functional implants (17%), these patients were significantly less satisfied than those with spontaneous ankylosis. TDR, nowadays, is an approved procedure. Proof that long-term results of TDR implantation in DDD are at least as good as fusion results is still missing.