European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society
-
Comparative Study
Preoperative transarterial embolization of vertebral metastases.
The aim of this study was to evaluate the impact of preoperative devascularization of spinal metastases in relation to the preembolization tumor vascularization degree and in relation to the intraoperative blood loss. Twenty-four patients underwent preoperative transarterial embolization of hypervascular spinal metastases. Each tumor was assigned a vascularization grade (I-III) according to tumor blush after contrast agent injection in the main feeding artery. ⋯ The surgeons concluded that radical tumor resection after embolization was facilitated. Intraoperative blood loss is not correlated with the pre-interventional vascularization degree, if complete devascularization can be achieved with embolization. Preoperative embolization of vertebral hypervascular tumors is safe, effective and facilitates tumor resection.
-
Comparative Study
Biomechanical comparison of anterior cervical spine locked and unlocked plate-fixation systems.
Three different anterior plate-fixation systems are available for the stabilisation of the cervical spine: (1) the cervical spine locking plate (CSLP), (2) dynamic plates allowing vertical migration of the fixation screws, and (3) various types of plates that are secured with either monocortical or bicortical unlocked screws. Unicortical screw purchase does not involve the risk of posterior cortex penetration and possible injuries to the spinal cord. The development of locking plates with unicortical screw-fixation and intrinsic stability of the screw-plate interface, via an angle-stabilised connection, was an attempt to increase the stability of unicortical screw-fixation systems. ⋯ Direct comparison of the fixed cervical spine segments with unlocked and locked anterior-plate fixation did not demonstrate significant differences. This in vitro study documented that neither locked nor unlocked anterior-plate fixation can increase stability in all modes of testing. H-plate spondylodesis with unlocked screws seems to provide sufficient mechanical integrity in most cases of monosegmental lesions.
-
Comparative Study
Morphological changes of the ligamentum flavum as a cause of nerve root compression.
The ligamentum flavum is considered to be one of the important causes of radiculopathy in lumbar degenerative disease. Although there have been several reports anatomically examining the positional relationship between the ligamentum flavum and nerve root, there are few reports on ventral observation. The purpose of this study is to clarify the shape of the ligamentum flavum seen ventrally, and to obtain anatomic findings related to nerve root compression. ⋯ Proximal bulging indicates the type with the cranial portion bulging from the subarticular zone to the foraminal zone of the ligamentum flavum. In this type associated with a decrease in disc height, nerve root compression was frequently observed. Thus, we could more realistically grasp the relationship between bulging morphology of the ligamentum flavum and nerve root compression.
-
Registration is a critical and important process in maintaining the accuracy of CT-based image-guided surgery. The aim of this study was to evaluate the effects of the area of intraoperative data sampling and number of sampling points on the accuracy of surface-based registration in a CT-based spinal-navigation system, using an optical three-dimensional localizer. A cadaveric dry-bone phantom of the lumbar spine was used. ⋯ The use of 20 surface points on the lamina usually allows surgeons to carry out sufficiently accurate registration to conduct computer-aided spine surgery. In the case of severe spondylosis, however, it might be difficult to digitize the surface points from the lamina, due to a hypertrophic facet joint or the deformity of the lamina and noisy sampling data. In such cases, registration accuracy can be improved by combining use of the 20 surface points on the lamina with surface points on other zones, such as on the both sides of the spinous process.