European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society
-
Comparative Study
Comparison of the biomechanical effects of posterior and anterior spine-stabilizing implants.
Posteriorly and anteriorly fixed implants for stabilizing unstable spines are available on the market. Differences in the biomechanical behavior of these implant types are not yet fully clear. They were investigated using three-dimensional nonlinear finite element models of the lumbar spine in an intact state, with an anteriorly fixed MACS-TL implant and with posteriorly fixed internal fixators. ⋯ In the period immediately after surgery, patients with osteoporotic vertebrae and who are treated with an internal spinal fixation device should therefore avoid excessive flexion. This study adds new information about the mechanical behavior of the lumbar spine after insertion of posterior and anterior spine-stabilizing implants. This information improves our biomechanical understanding of the spine.
-
One of the main limitations of vertebroplasty is the excessive pressure required to inject a sufficient amount of cement into a vertebral body. Based on previous work that shows that approximately 95% of the injection pressure is required to deliver the cement through the cannula, we proposed a new cannula design with a larger internal diameter in the proximal section. The objective of this study is to determine whether the new cannula geometry significantly reduces the delivery pressure and eases cement injection during vertebroplasty. ⋯ Specifically, when the internal diameter of the proximal section was increased by a factor of two, which is clinically feasible, the delivery pressure dropped by about 63%. The redesigned cannula appears to have the potential to improve vertebroplasty. The key benefits are that (1) it eases cement injection, (2) it can be easily integrated into the existing procedure, and (3) it is cost-effective.
-
A prospective radiographic study of the influence of total disc replacement on spinal sagittal balance. The goal of this study was to prospectively determine the effect of a single-level, total disc replacement on the sagittal balance of the spine, especially on sacral tilt (ST), pelvic tilt (PT), and lumbar lordosis. It has been shown that lumbar fusion may deleteriously alter the sagittal balance of the spine, including a decrease in the ST and lumbar lordosis. ⋯ In the present study with use of a motion-preserving Maverick prosthesis, it appears that the patient is able to maintain the preoperative sagittal balance. The prosthesis has enough freedom of motion to allow the patient to maintain the natural sagittal and spinopelvic balance needed to prevent potential undue stress on the muscles and the sacroiliac joint. Although the number of patients is small, this is the first study to our knowledge that evaluates the sagittal balance after motion-preserving total disc arthroplasty.
-
The objective of this study was to determine atlanto-axial bone morphometric measurements related to screw transarticular fixation technique. One hundred helical computerized tomography (helical CT) scans with volumetric acquisition, including the first and the second cervical vertebrae, were studied. The screw insertion axis according to the Magerl technique for C1-C2 transarticular fixation was the referential to select the correct oblique axial and oblique parasagittal planes obtained with multiplanar reconstruction (MPR) on helical CT. ⋯ In 6% of patients the potential risk was identified bilaterally. There is a great variation in the maximum and minimum values of the anatomic measurements. Therefore preoperative CT scans are very important to identify type II cases, such that the surgeon may preoperatively define the bony anatomy trough which the screws will pass.
-
Comparative Study
Atlantoaxial fusion using anterior transarticular screw fixation of C1-C2: technical innovation and biomechanical study.
This study is an attempt to describe a new technique for anterior transarticular screw fixation of the atlantoaxial joints, and to compare the stability of this construct to posterior transarticular screw fixation with and without laminar cerclage wiring. Nine human cadaveric specimens were included in this study. The C1-C2 motion segment was instrumented using either anterior transarticular screws (group 1), posterior transarticular screws alone (group 2), or posterior screws with interlaminar cerclage wires (group 3). ⋯ Anterior transarticular screw fixation of the atlantoaxial spine has several advantages over posterior fixation techniques, and is as stable as posterior transarticular fixation in all clinically significant planes of motion. The addition of posterior interlaminar cerclage wiring further improves resistance to flexion-extension forces. Anterior transarticular screw fixation of the atlantoaxial joint is a useful technique for achieving C1-C2 stabilization.