European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society
-
Posterior instrumentation of the occipito-cervical spine has become an established procedure in a variety of indications. The use of rod-screw systems improved posterior instrumentation as it allows optimal screw positioning adapted to the individual anatomic situation. However, there are still some drawbacks concerning the different implant designs. ⋯ Pedicle screw instrumentation tended to be more stable compared to lateral mass screws; nevertheless, significant differences were observed only for lateral bending. As the experimental design precluded any cyclic testing, the data represent only the primary stability of the implants. In summary, this study showed that posterior instrumentation of the cervical spine using the new Neon Occipito Cervical System improves primary biomechanical stability compared to the CerviFix System and the Olerud Cervical Rod Spinal System.
-
Comparative Study
Range of global motion of the cervical spine: intraindividual reliability and the influence of measurement device.
Range of motion tests are often employed in the quantification of musculoskeletal impairment and in the assessment of the efficacy of therapeutic interventions. The aim of the present study was to compare the absolute values for, and the day-to-day reliability of, measures of cervical spinal mobility made with two computerised motion analysis devices. The ranges of cervical flexion, extension, lateral bending, axial rotation, and axial rotation in flexion and extension were determined for 19 volunteers using both the CA6000 Spine Motion Analyser and the Zebris CMS system; all measures were repeated on a second occasion 1-3 days later. ⋯ Each device is highly reliable in itself and can be used with confidence in longitudinal studies. The establishment of 'normal' values for the primary motions should take account of the slight differences observed between devices. Normal values for rotation in flexion or extension cannot be established until the source of the device-dependent difference is identified.
-
Concomitant traumatic injuries in the upper cervical spine are often encountered and rarely reported. We examined the data concerning 784 patients with cervical spine injuries following trauma, including 116 patients with upper cervical spine injuries. Twenty-six percent of patients with upper cervical spine injuries (31 cases) were found to have combined injuries involving either the upper or the upper and lower cervical spine. ⋯ A total of 1.7% of patients with lower cervical spine injuries had a combined injury in the upper cervical spine. A comprehensive therapeutic schedule is outlined. Combined injuries in the upper cervical spine should be sought in any patient with a cervical spine injury.
-
We report a case of 14-year-old male patient with osteoid osteoma of the cervical spine. Magnetic resonance imaging (MRI) revealed a large dumbbell-shaped paravertebral tumor in the region of the exiting left C6 nerve. ⋯ The resected specimen exhibited extensive vascularization of the osteoid tissue. The case is presented because MRI did not allow a specific diagnosis of osteoid osteoma, and suggested the tumor was larger than in reality it was, by also depicting the reactive inflammation around the tumor as if it were part of the tumor.
-
Most hangman's fractures are treated conservatively. If surgery is indicated, an anterior approach using a C2/C3 graft and plate fusion is usually preferred. Another surgical method according to Judet is direct transpedicular osteosynthesis by the dorsal approach. ⋯ Follow-up ranged from 12 to 57 months (mean 33.3 months). No intraoperative or early or late postoperative complications were apparent. This new aspect of the surgical procedure ensures highly accurate screw placement and minimal risks, and fully achieves the "physiological" internal fixation.