European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society
-
Clinical Trial
A new approach to computer-aided spine surgery: fluoroscopy-based surgical navigation.
A new computer-based navigation system for spinal surgery has been designed. This was achieved by combining intraoperative fluoroscopy-based imaging using conventional C-arm technology with free-hand surgical navigation principles. Modules were developed to automate digital X-ray image registration. ⋯ Stereotactic instruments and graphical user interfaces for image-interactive transpedicular screw insertion have been developed. A detailed validation of the system was performed in the laboratory setting and throughout an early clinical trial including eight patients in two spine centers. Based on the resulting data, the new technique promises improved accuracy and safety in open and percutaneous spinal surgery.
-
Comparative Study
Odontoid fractures: high complication rate associated with anterior screw fixation in the elderly.
This study is a retrospective analysis of patients older than 65 years with odontoid fractures. The series consisted of 29 consecutive patients with odontoid fractures (18 women, mean age 78, range 66-99 years). Twenty-six patients were neurologically intact, Frankel E, whereas three had neurological symptoms: two Frankel D and one Frankel C. ⋯ We conclude that anterior screw fixation according to Böhler is associated with an unacceptably high rate of problems in the elderly. Probable causes may be osteoporosis with comminution at the fracture site, or stiffness of the cervical spine preventing ideal positioning of the screws. As non-operative treatment also often fails, the method of choice seems to be posterior C1-C2 fusion.
-
Comparative Study
Nucleus pulposus inhibits the axonal outgrowth of cultured dorsal root ganglion cells.
Although it is well established that nucleus pulposus cells may induce structural and functional changes in adjacent nerve roots when placed epidurally, it is not known whether this is due to direct neurotoxic effects or whether the nerve roots are affected indirectly by reduction of nutrition and inflammatory/immunologic mechanisms. In the present study we assessed the effects of various tissues on cultured dorsal root ganglions from newborn rats. ⋯ The study thus showed that there are direct axonotoxic effects induced by the nucleus pulposus, and since frozen nucleus pulposus did not have any effects, it may be assumed that the mechanisms are related to substances produced by the nucleus pulposus cells. The presented model allows for future studies on the neurotoxic properties of nucleus pulposus cell-derived candidate substances.
-
Comparative Study
Early histologic changes in lower lumbar discs and facet joints and their correlation.
Biomechanical and histologic studies have highlighted the close functional relationship between lumbar discs and their associated facet joints, and it is conceivable that their degenerative changes are interdependent. However, separation of cause from effect remains controversial. Hitherto, no study in humans has correlated the changes histologically. ⋯ There was no correlation between changes in discs and the associated facet joints at either level. The results of the study showed that microscopic changes are seen in the disc and facet joints from an early age and can be quite marked in some individuals before the age of 40 years. A correlation of degenerative changes within the FSU could not be established.
-
Transarticular C1/2 screws are widely used in posterior cervical spine instrumentation. The use of pedicle screws in the cervical spine remains uncommon. Due to superior biomechanical stability compared to lateral mass screws, pedicle screws can be used, especially for patients with poor bone quality or defects in the anterior column. ⋯ Therefore, this technique may be used in a clinical setting, as it offers improved accuracy and reduced radiation dose for the patient and the medical staff. Nevertheless, users should take note of known sources of possible faults causing inaccuracies in order to prevent iatrogenic damage. Small pedicles, with a diameter of less than 4.0 mm, may not be suitable for pedicle screws.