European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society
-
Halm-Zielke instrumentation (HZI) was developed to eliminate the disadvantages of Zielke instrumentation (VDS) in terms of lack of primary stability and a kyphogenic effect. HZI is an anterior double-rod system. The system is composed of a lid-plate, which is fixed at the lateral aspect of the vertebral body with two screws, a sunk screw anteriorly and a VDS screw posteriorly. ⋯ All patients were treated without any additional external immobilization. In our opinion, HZI is a major improvement on the original Zielke VDS. It eliminates the kyphogenic effect and provides primary stability.
-
Comparative Study
Functional outcome after posterolateral spinal fusion using pedicle screws: comparison between primary and salvage procedure.
Lumbar spinal fusion is a commonly performed surgical procedure, yet both the indications for its performance and its results remain controversial. It is generally believed that apart from situations where obvious measurable instability exists, a repeat surgical procedure such as spinal fusion does not improve the functional outcome in more than an average of 50% of cases. The aim of this study was to analyse functional outcome after posterolateral lumbar or lumbosacral spinal fusion, comparing primary and salvage procedures. ⋯ This study demonstrates that a posterolateral spinal fusion can be effectively used as a salvage procedure. The functional and radiological outcome of the patients with revision surgery did not differ from those of the group of patients who underwent primary surgery. There was, however a clear indication of inferior social functioning after revision surgery.
-
We report a unique complication caused by the rod of a Harrington instrumentation device, which resulted in spinal stenosis and myelopathy. A literature review revealed no previous causes of direct spinal cord impingement caused by the rod of a Harrington device. In this case, years after the initial operation, the rod penetrated the lamina at the junction between a thoracic and a lumbar curve, causing spinal stenosis and myelopathy. We conclude that regular control of the position of the device and awareness of possible late neurological complications are necessary to identify such complications as early as possible.
-
Randomized Controlled Trial Comparative Study Clinical Trial
Cervical radiculopathy: pain, muscle weakness and sensory loss in patients with cervical radiculopathy treated with surgery, physiotherapy or cervical collar. A prospective, controlled study.
This prospective, randomised study compares the efficacy of surgery, physiotherapy and cervical collar with respect to pain, motor weakness and sensory loss in 81 patients with long-lasting cervical radiculopathy corresponding to a nerve root that was significantly compressed by spondylotic encroachment, with or without an additional bulging disk, as verified by MRI or CT-myelography. Pain intensity was registered on a visual analogue scale (VAS), muscle strength was measured by a hand-held dynamometer, Vigorometer and pinchometer. Sensory loss and paraesthesia were recorded. ⋯ With respect to absolute muscle strength of the affected sides, there were no differences at control 1. At control 2, the surgery group performed some-what better than the two other groups but at control 3 there were no differences between the groups. We conclude that pain intensity, muscle weakness and sensory loss can be expected to improve within a few months after surgery, while slow improvement with conservative treatments and recurrent symptoms in the surgery group make the 1-year results about equal.