Abdominal imaging
-
To determine the most common errors of epinephrine administration during severe allergic-like contrast reaction management using high-fidelity simulation surrogates. ⋯ Epinephrine administration errors are common. Many radiologists fail to administer albuterol as the first-line treatment for mild bronchospasm and fail to flush the IV catheter when administering IV epinephrine. High-fidelity contrast reaction scenarios can be used to identify areas for training improvement.
-
To investigate early diffusion-weighted imaging (DWI) at 30-days post-yttrium-90 (Y-90) radioembolization as a predictor of treatment response and survival in unresectable infiltrative hepatocellular carcinoma (HCC) with portal vein thrombosis (PVT). ⋯ A 30% increase in ADC value at 30-days measured post Y90 is a reproducible early imaging response biomarker predicting tumor response and prolonged survival following Y-90 therapy in infiltrative HCC with PVT.
-
To determine whether application of a high-acceleration parallel acquisition can provide three-dimensional (3D)-fat-suppressed T1-weighted gradient-recalled-echo (T1W-GRE) imaging at 3T for liver MR imaging. ⋯ With the use of high AFs, HR 3D-T1W-GRE imaging was demonstrated to be clinically more feasible and advantageous than the conventional 3D-T1W-GRE.
-
The purpose of this study is to compare CT images of the pancreas reconstructed with model-based iterative reconstruction (MBIR), adaptive statistical iterative reconstruction (ASiR), and filtered back projection (FBP) techniques for image quality and pancreatic duct (PD) depiction. Data from 40 patients with contrast-enhanced abdominal CT [CTDIvol: 10.3 ± 3.0 (mGy)] during the late arterial phase were reconstructed with FBP, 40% ASiR-FBP blending, and MBIR. Two radiologists assessed the depiction of the main PD, image noise, and overall image quality using 5-point scale independently. ⋯ No significant differences in CT values of the pancreatic parenchyma were noted among FBP, 40% ASiR, and MBIR images (P > 0.05). Objective image noise was significantly lower and CNR of the PD was higher with MBIR than with FBP and 40% ASiR (all P < 0.05). Our results suggest that pancreatic CT images reconstructed with MBIR have lower image noise, better image quality, and higher conspicuity and CNR of the PD compared with FBP and ASiR.
-
To determine the CT findings and assess their diagnostic performance in differentiating early perforated appendicitis from nonperforated appendicitis, and to compare therapeutic approaches and clinical outcomes between two types of appendicitis. Our retrospective study was approved by our institutional review board and informed consent was waived. From July 2012 to July 2013, 339 patients [mean age 40.8 years; age range 19-80 years; 183 male (mean age 40.5 years; age range 19-79 years) and 156 female (mean age 41.2 years; age range 19-80 years)] who underwent appendectomy with preoperative CT examination for suspected acute appendicitis were included, with exclusion of 37 patients with specific CT findings for advanced perforated appendicitis. ⋯ The transverse diameter of the appendix (≥11 mm) had the highest sensitivity (62.7%) and focal wall defect in the appendiceal wall showed the highest specificity (98.8%). The prevalence of surgical drainage was higher (p = 0.001) and the mean hospital stay was approximately one day longer (p < 0.001) in the early perforated group than nonperforated group. CT can be helpful in differentiating early perforated appendicitis from nonperforated appendicitis, although the sensitivity of the evaluated findings was somewhat limited.