Anaesthesia
-
Review Meta Analysis Comparative Study
Comparative efficacy and safety of the Ambu(®) AuraOnce(™) laryngeal mask airway during general anaesthesia in adults: a systematic review and meta-analysis.
The Ambu AuraOnce™ laryngeal mask is a non-inferior alternative to the LMA Classic and the LMA Unique.
pearl -
Various experimental studies in animals have shown that general anaesthetics are potentially toxic to the developing brain. By inducing apoptosis or interfering with neurogenesis, anaesthetic exposure during a critical period of neuronal development can have significant impact on neurocognitive function later in life. It remains controversial whether these experimental results can be transferred to human beings and this is under intensive scientific evaluation. ⋯ Anaesthesia is not an end in itself, but necessary to facilitate surgical procedures. There is evidence that maintaining physiological conditions is important for the overall outcome following anaesthesia and surgery. Until proven otherwise, it can be recommended to keep anaesthesia and surgery as short as possible, to use short-acting drugs and/or a combination of general anaesthesia and multimodal pain therapy including systemic analgesics, and local or regional anaesthesia, to reduce the overall drug dosage.
-
As part of the 5th National Audit Project of the Royal College of Anaesthetists and the Association of Anaesthetists of Great Britain and Ireland concerning accidental awareness during general anaesthesia, we issued a questionnaire to every consultant anaesthetist in each of 46 public hospitals in Ireland, represented by 41 local co-ordinators. The survey ascertained the number of new cases of accidental awareness becoming known to them for patients under their care or supervision for a calendar year, as well as their career experience. Consultants from all hospitals responded, with an individual response rate of 87% (299 anaesthetists). ⋯ None of the 46 hospitals had a policy to prevent or manage awareness. Similar to the results of a larger survey in the UK, the disparity between the incidence of awareness as known to anaesthetists and that reported in trials warrants explanation. Compared with UK practice, there appears to be greater use of depth of anaesthesia monitoring in Ireland, although this is still infrequent.
-
Comparative Study
The intubation scoop (i-scoop) - a new type of laryngoscope for difficult and normal airways.
The i-scoop is an intubation device with a curved guiding bar with laterally located lenses at its tip, rather than a blade. Twenty-five anaesthesiologists intubated a manikin that simulated first a normal and then a difficult airway. All participants were able to intubate the difficult airway with a good view of the glottis using the i-scoop. ⋯ Advance DAB (n = 1) and the GlideScope DL Trainer (n = 1) (p < 0.001, success rate of i-scoop vs all 12 laryngoscopes combined). In contrast to all other videolaryngoscopes, intubation of the normal airway with the i-scoop was achieved even faster than with the Macintosh laryngoscope (p < 0.02). The i-scoop outperformed all other laryngoscopes in both difficult and normal airways, and therefore has potential as an easier and safer alternative to present devices.