A comparison of plasma levobupivacaine concentrations following transversus abdominis plane block and rectus sheath block.
Levobupivacaine is commonly used as the local anaesthetic of choice in peripheral nerve blocks, but its pharmacokinetics have not been fully investigated. We compared the changes in plasma concentrations of levobupivacaine following transversus abdominis plane block and rectus sheath block. ⋯ The mean maximum plasma concentration (Cmax) and mean time to reach Cmax (Tmax) as determined by non-linear regression analysis were 1.05 μg.ml(-1) and 32.4 min in the transversus abdominis plane group and 0.95 μg.ml(-1) and 60.9 min in the rectus sheath group, respectively. The plasma concentration of levobupivacaine peaked earlier in the transversus abdominis plane group than in the rectus sheath group and the maximum plasma concentration depended on the dose administered but not the procedure.
-
Comparative Study
Comparison of seven videolaryngoscopes with the Macintosh laryngoscope in manikins by experienced and novice personnel.
Videolaryngoscopy is often reserved for 'anticipated' difficult airways, but thereby can result in a higher overall rate of complications. We observed 65 anaesthetists, 67 residents in anaesthesia, 56 paramedics and 65 medical students, intubating the trachea of a standardised manikin model with a normal airway using seven devices: Macintosh classic laryngoscope, Airtraq(®) , Storz C-MAC(®) , Coopdech VLP-100(®) , Storz C-MAC D-Blade(®) , GlideScope Cobalt(®) , McGrath Series5(®) and Pentax AWS(®) ) in random order. Time to and proportion of successful intubation, complications and user satisfaction were compared. ⋯ All groups needed significantly more attempts using the Airtraq and Pentax AWS (all p < 0.05). Devices with a Macintosh-type blade (classic laryngoscope and C-MAC) scored highest in user satisfaction. Our results underline the importance of variability in device performance across individuals and staff groups, which have important implications for which devices hospital providers should rationally purchase.
-
Comparative Study
A comparison of intranasal dexmedetomidine for sedation in children administered either by atomiser or by drops.
Intranasal dexmedetomidine has been used successfully for sedation in children. A mucosal atomisation device delivers an atomised solution to the nasal mucosa which facilitates rapid and effective delivery of medication to the systemic circulation. We compared intranasal delivery of dexmedetomidine in a dose of 3 μg.kg(-1) by either atomiser or drops from a syringe in children < 3 years old undergoing transthoracic echocardiography. ⋯ Sedation tended to be less successful in older children (p = 0.028, OR 0.949, 95% CI 0.916-0.983). There were no significant complications. We conclude that both modes of dexmedetomidine administration are equally effective, although increasing age of the child was associated with a decreased likelihood of successful sedation.
-
This study sought to identify changes in hepatic flood flow and cardiac output during prone positioning on surgical bolsters in awake volunteers, and was prompted by a local incident of significant hepatic dysfunction following surgery in the prone position. Cardiac output was determined using the non-invasive Peñáz technique, and plasma disappearance rate of indocyanine green (ICG-PDR) was measured as a surrogate maker for hepatic blood flow along with serum hepatic enzyme assays. Measurements were made after one hour in supine, prone and returned supine positions. ⋯ There were significant changes in the disappearance rate of indocyanine green, which decreased this from mean (SD) 31.1 (9.70) supine to 19.6 (4.37)%.min prone, respectively (p = 0.02), increasing on return to the supine position to 24.6 (5.54)%.min (p = 0.019). Cardiac output was also significantly reduced when changing from the supine to the prone position, from mean (SD) 4.7 (1.0 to 3.5 (1.1) (l.min(-1) ), respectively (p = 0.002). We demonstrated an acute and reversible change in both hepatocellular function and cardiac output associated with the prone position.