Anaesthesia
-
Coagulopathy and severe bleeding are associated with high mortality. We evaluated haemostatic treatment guided by the functional viscoelastic haemostatic assays, thromboelastography or rotational thromboelastometry in bleeding patients. We searched for randomised, controlled trials irrespective of publication status, publication date, blinding status, outcomes published or language from date of inception to 5 January 2016 in six bibliographic databases. ⋯ There was no difference in proportion needing surgical re-interventions (RR (95% CI) 0.75 (0.50-1.10); I2 = 0%, 9 trials, 887 participants). Trial sequential analysis of mortality suggests that only 54% of the required information size has been reached so far. Transfusion strategies guided by thromboelastography or rotational thromboelastometry may reduce the need for blood products in patients with bleeding, but the results are mainly based on trials of elective cardiac surgery involving cardiopulmonary bypass, with low-quality evidence.
-
Randomized Controlled Trial
The effects of tracheal tube cuffs filled with air, saline or alkalinised lidocaine on haemodynamic changes and laryngotracheal morbidity in children: a randomised, controlled trial.
We studied the effects of tracheal tube cuffs filled with air, saline or alkalinised lidocaine on haemodynamic changes during tracheal extubation and postoperative laryngotracheal morbidity in children. We randomly allocated 164 children aged 3-13 years undergoing general anaesthesia to one of four groups; tracheal tube cuffs filled with air (n = 41); saline (n = 41); alkalinised lidocaine 0.5% (n = 41); or alkalinised lidocaine 1% (n = 41). Intracuff pressure was monitored and maintained below 20 cmH2 O. ⋯ The mean (SD) increases in heart rate after tracheal extubation compared with before extubation were 14.2 (7.6) beats.min-1 , 15.5 (13.1) beats.min-1 , 5.2 (9.6) beats.min-1 and 4.1 (6.6) beats.min-1 in the air, saline, 0.5% and 1% alkalinised lidocaine groups, respectively (p < 0.001). The incidence of sore throat 8 h after tracheal extubation was 22.0% in the air-filled group, 9.8% in the saline group, 4.9% in the 0.5% alkalinised lidocaine group and 2.4% in the 1% alkalinised lidocaine group, p = 0.015. We conclude that filling the tracheal tube cuff with alkalinised lidocaine-filled reduces the haemodynamic response to tracheal extubation and postoperative laryngotracheal morbidity in children.
-
Randomized Controlled Trial Comparative Study
A randomised controlled trial comparing transnasal humidified rapid insufflation ventilatory exchange (THRIVE) pre-oxygenation with facemask pre-oxygenation in patients undergoing rapid sequence induction of anaesthesia.
Pre-oxygenation is an essential part of rapid sequence induction of general anaesthesia for emergency surgery, in order to increase the oxygen reservoir in the lungs. We performed a randomised controlled trial of transnasal humidified rapid insufflation ventilatory exchange (THRIVE) pre-oxygenation or facemask pre-oxygenation in patients undergoing emergency surgery. Twenty patients were allocated to each group. ⋯ No airway rescue manoeuvres were needed, and there were no differences in the number of laryngoscopy attempts between the groups. In spite of this, patients in the THRIVE group had a significantly longer apnoea time of 248 (71) s compared with 123 (55) s in the facemask group (p < 0.001). Transnasal humidified rapid insufflation ventilatory exchange is a practicable method for pre-oxygenating patients during rapid sequence induction of general anaesthesia for emergency surgery; we found that it maintained an equivalent blood gas profile to facemask pre-oxygenation, in spite of a significantly longer apnoea time.
-
Limited resources and access to healthcare in sub-Saharan Africa are associated with high rates of malnourished children, although many countries globally are demonstrating increasing childhood obesity. This study evaluated how well current age- or height-based formulae estimate the weight of children undergoing surgery in Zambia. All children under 14 years of age presenting for elective surgery at the University Teaching Hospital, Lusaka, had both height and weight measured. ⋯ The Broselow tape outperformed all the age-based formulae, demonstrating the lowest median percentage error of -5.8%, with 46.0% of estimates falling within 10% of the actual measured weight (p < 0.001). Of the 1111 children who were eligible for World Health Organization growth standard appraisal, 88 (8%) met the weight criteria for severe acute malnutrition. Our results are consistent with other studies in finding that the Broselow tape is the best estimator of weight in a lower middle-income country, followed by the original Advanced Paediatric Life Support formula if the Broselow tape is unavailable.