Anaesthesia
-
In 2011, the Fourth National Audit Project (NAP4) reported high rates of airway complications in adult intensive care units (ICUs), including death or brain injury, and recommended preparation for airway difficulty, immediately available difficult airway equipment and routine use of waveform capnography monitoring. More than 80% of UK adult intensive care units have subsequently changed practice. Undetected oesophageal intubation has recently been listed as a 'Never Event' in UK practice, with capnography mandated. ⋯ Death or serious harm occurring secondary to complications of airway management in the last 5 years was reported in 19% of paediatric intensive care units and in 26% of neonatal intensive care units. We conclude that major gaps in optimal airway management provision exist in UK paediatric intensive care units and especially in UK neonatal intensive care units. Wider implementation of waveform capnography is necessary to ensure compliance with the new 'Never Event' and has the potential to improve airway management.
-
Editorial Comment
Postoperative anaemia: balancing the risks of anaemia and transfusion.