Anaesthesia
-
Indications for using supraglottic airway devices have widened over time and they now hold a prominent role in guidelines for difficult airway management. We aimed to describe the use of supraglottic airway devices in difficult airway management. We included adult patients undergoing general anaesthesia registered in the Danish Anaesthesia Database from 2008 to 2012 whose airway management had been recorded as difficult, defined as: ≥ 3 tracheal intubation attempts; failed tracheal intubation; or difficult facemask ventilation. ⋯ Supraglottic airway devices were used or use was attempted in 607 cases of difficult airway management (12.4% (95%CI 11.5-13.3%)), and were successful in 395 (65.1% (95%CI 61.2-68.8%)) cases. In 'cannot intubate, cannot facemask ventilate' situations, supraglottic airway devices were used in 86 (18.9% (95%CI 15.6-22.8%)) of 455 records and were successful in 54 (62.8% (95%CI 52.2-72.3%)) cases. We found that supraglottic airway devices are not widely used in the management of the difficult airway despite their prominent role in difficult airway management guidelines.
-
Randomized Controlled Trial Comparative Study
Fibrinogen concentrate vs. fresh frozen plasma for the management of coagulopathy during thoraco-abdominal aortic aneurysm surgery: a pilot randomised controlled trial.
Major vascular surgery is frequently associated with significant blood loss and coagulopathy. Existing evidence suggests hypofibrinogenaemia develops earlier than other haemostatic deficiencies during major blood loss. The purpose of this study was to assess whether the use of an infusion of fibrinogen concentrate to prevent and treat hypofibrinogenaemia during surgery resulted in satisfactory haemostasis, removing or reducing the need for blood component transfusion. ⋯ All patients in both groups were assessed by the surgeon to have satisfactory haemostasis at the end of surgery. Mean (SD) postoperative fibrinogen concentrations were similar in patients allocated to fresh frozen plasma and fibrinogen concentrate (1.6 (0.3) g.l-1 vs. 1.6 (0.2) g.l-1 ; p = 0.36) but the mean (SD) international normalised ratio and activated partial thromboplastin time ratio were lower in patients allocated to fresh frozen plasma (1.1 (0.1) vs. 1.8 (0.3); p < 0.0001 and 1.1 (0.2) vs. 1.7 (0.5); p = 0.032, respectively). Fibrinogen concentrate may be used as an alternative to fresh frozen plasma in the treatment of coagulopathy during thoraco-abdominal aortic aneurysm repair.