Anaesthesia
-
Randomized Controlled Trial Comparative Study
A randomised controlled trial of shoulder block vs. interscalene brachial plexus block for ventilatory function after shoulder arthroscopy.
The shoulder block may impair ventilatory function and diaphragmatic movement less than the interscalene brachial plexus block. We randomly allocated 30 adults who underwent shoulder arthroscopy under general anaesthesia to ultrasound-guided shoulder block or interscalene block with 20 ml bupivacaine 0.5%. ⋯ The mean (SD) numeric rating scale pain scores at rest after shoulder block were higher than after interscalene block at two postoperative hours, 1.4 (1.2) vs. 0.3 (0.7), p = 0.02, but lower at 24 postoperative hours, 1.3 (1.3) vs. 3.4 (2.3), p = 0.008. Mean (SD) pain scores on movement in the shoulder and interscalene blocks were similar, with respective values of 1.9 (1.9) vs. 0.7 (1.2), p = 0.13 at two postoperative hours and 3.7 (2.3) vs. 5.3 (2.5), p = 0.41, at 24 postoperative hours.
-
The cost effectiveness of reusable vs. single-use flexible bronchoscopy in the peri-operative setting has yet to be determined. We therefore aimed to determine this and hypothesised that single-use flexible bronchoscopes are cost effective compared with reusable flexible bronchoscopes. We conducted a systematic review of the literature, seeking all reports of cross-contamination or infection following reusable bronchoscope use in any clinical setting. ⋯ The cost per use of a single-use flexible bronchoscope was £220 sterling. The cost effectiveness analysis demonstrated that reusable flexible bronchoscopes have a cost per patient use of £511 sterling due to the costs of treatment of infection. The findings from this study suggest benefits from the use of single-use flexible bronchoscopes in terms of cost effectiveness, cross-contamination and resource utilisation.
-
Practice Guideline
Difficult Airway Society guidelines for awake tracheal intubation (ATI) in adults.
Awake tracheal intubation has a high success rate and a favourable safety profile but is underused in cases of anticipated difficult airway management. These guidelines are a comprehensive document to support decision making, preparation and practical performance of awake tracheal intubation. We performed a systematic review of the literature seeking all of the available evidence for each element of awake tracheal intubation in order to make recommendations. ⋯ We recognise that there are a range of techniques and regimens that may be effective and one such example technique is included. Breaking down the key practical elements of awake tracheal intubation into sedation, topicalisation, oxygenation and performance might help practitioners to plan, perform and address complications. These guidelines aim to support clinical practice and help lower the threshold for performing awake tracheal intubation when indicated.
-
Spinal hypotension is a common and clinically important problem during caesarean section. Current consensus recommendations for resource-rich settings suggest the use of a titrated phenylephrine infusion, in combination with fluid coloading, for prevention of maternal hypotension. In resource-limited settings, where syringe drivers are unavailable, these recommendations advise the addition of 500 μg phenylephrine to the first 1 l of intravenous fluid given after initiation of spinal anaesthesia, with additional vasopressor boluses as required. ⋯ The six highest systolic arterial pressure readings occurred in the phenylephrine infusion group (range 166-188 mmHg), and there were four instances of bradycardia (heart rate < 50 beats.min-1 ) with preserved systolic arterial pressure in each group. There were no adverse clinical sequelae, and no differences in neonatal Apgar scores in either group. The consensus recommendation for phenylephrine and fluid co-administration in resource-limited settings appears effective in preventing maternal hypotension, but at the cost of sporadic systolic hypertension.