Anaesthesia
-
Review Comparative Study
Anatomic accuracy of airway training manikins compared with humans.
Airway simulators, or training manikins, are frequently used in research studies for device development and training purposes. This study was designed to determine the anatomic accuracy of the most frequently used low-fidelity airway training manikins. Computerised tomography scans and ruler measurements were taken of the SynDaver® , Laerdal® and AirSim® manikins. ⋯ All three manikins were visually identifiable as outliers when plotting the first two dimensions from multidimensional scaling. In particular, the airway space between the epiglottis and posterior pharyngeal wall, through which airway devices must pass, was too large in all three manikins. SynDaver, Laerdal and AirSim manikins do not have anatomically correct static dimensions in relation to humans and these inaccuracies may lead to imprecise airway device development, negatively affect training and cause over-confidence in users.
-
Modern four-factor prothrombin complex concentrate was designed originally for rapid targeted replacement of the coagulation factors II, VII, IX and X. Dosing strategies for the approved indication of vitamin K antagonist-related bleeding vary greatly. They include INR and bodyweight-related protocols as well as fixed dose regimens. ⋯ In patients with a high risk for thromboembolic complications, e.g. cardiac surgery, the administration of an initial half-dose bolus (12.5 IU.kg-1 ) should be considered. A second bolus may be indicated if coagulopathy and microvascular bleeding persists and other reasons for bleeding are largely ruled out. Tissue-factor-activated, factor VII-dependent and heparin insensitive point-of-care tests may be used for peri-operative monitoring and guiding of prothrombin complex concentrate therapy.
-
Observational Study
A prospective observational study of the rapid detection of clinically-relevant plasma direct oral anticoagulant levels following acute traumatic injury.
In urgent clinical situations, such as trauma, urgent surgery or before thrombolysis, rapid quantification of direct oral anticoagulant plasma drug levels is warranted. Using the ClotPro® analyser, we assessed two novel viscoelastic tests for detection of clinically-relevant plasma drug levels in trauma patients. The ecarin clotting time was used to assess the plasma concentration of dabigatran and Russell´s viper venom clotting time to determine the plasma concentration of direct factor Xa inhibitors. ⋯ Detection of drug levels ≥ 100 ng.ml-1 was also investigated: for dabigatran, an ecarin clotting time ≥ 315 seconds yielded 92% sensitivity and 100% specificity; while Russell´s viper venom clotting time cut-offs of 191, 188 and 196 seconds were calculated for apixaban (67% sensitivity, 88% specificity), edoxaban (100% sensitivity, 75% specificity) and rivaroxaban (100% sensitivity, 91% specificity), respectively. We have demonstrated strong positive correlations between plasma drug levels and clotting time values in the specific ClotPro assays. Cut-off values for detecting clinically-relevant drug levels showed high levels of sensitivity and specificity.