The effect of high-flow nasal oxygen flow rate on gas exchange in apnoeic patients: a randomised controlled trial.
High-flow nasal oxygen can be administered at induction of anaesthesia for the purposes of pre-oxygenation and apnoeic oxygenation. This intervention is claimed to enhance carbon dioxide elimination during apnoea, but the extent to which this occurs remains poorly quantified. The optimal nasal oxygen flow rate for gas exchange is also unknown. ⋯ After 4 minutes of apnoea, median (IQR [range]) arterial oxygen partial pressures in the 0 l.min-1, 70 l.min-1 and 120 l.min-1 groups were 24.5 (18.6-31.4 [12.3-48.3]) kPa; 36.6 (28.1-43.8 [9.8-56.9]) kPa; and 37.6 (26.5-45.4 [11.0-56.6]) kPa, respectively; p < 0.001. Median (IQR [range]) times to desaturate to 92% after the onset of apnoea in the 0 l.min-1, 70 l.min-1 and 120 l.min-1 groups, were 412 (347-509 [190-796]) s; 533 (467-641 [192-958]) s; and 531 (462-681 [326-1007]) s, respectively; p < 0.001. In conclusion, the rate of carbon dioxide accumulation in arterial blood did not differ significantly between apnoeic patients who received high-flow nasal oxygen and those who did not.
-
Review
Predicting time to asystole following withdrawal of life-sustaining treatment: a systematic review.
The planned withdrawal of life-sustaining treatment is a common practice in the intensive care unit for patients where ongoing organ support is recognised to be futile. Predicting the time to asystole following withdrawal of life-sustaining treatment is crucial for setting expectations, resource utilisation and identifying patients suitable for organ donation after circulatory death. This systematic review evaluates the literature for variables associated with, and predictive models for, time to asystole in patients managed on intensive care units. ⋯ This review identifies variables associated with time to asystole following withdrawal of life-sustaining treatment and summarises existing predictive models. Although several predictive models have been developed, their generalisability and performance varied. Further research and validation are needed to improve the accuracy and widespread adoption of predictive models for patients managed in intensive care units who may be eligible to donate organs following their diagnosis of death by circulatory criteria.
-
Randomized Controlled Trial Comparative Study
Comparison of the success rate of tracheal intubation between stylet and bougie with a hyperangulated videolaryngoscope: a randomised controlled trial.
Hyperangulated videolaryngoscopes are known to increase the success rate of tracheal intubation in the setting of difficult airway management when used with a stylet or bougie. However, there is controversy over which adjunct is more useful. This randomised study aimed to compare first attempt tracheal intubation success rate between a stylet and bougie when using a hyperangulated videolaryngoscope. ⋯ Each group had one patient (1%) where tracheal intubation was achieved after a third attempt. There was no significant difference in the occurrence of sore throat, dysphagia and hoarseness between the two groups. When difficult tracheal intubation is anticipated and a hyperangulated videolaryngoscope is used, the success rate of the first attempt is higher when a bougie is used compared with a stylet.