Academic emergency medicine : official journal of the Society for Academic Emergency Medicine
-
Despite some focus on the use of intraosseous (IO) catheters to obtain laboratory samples, very little is known about the potential for obtaining other forms of clinical data. Largely unstudied is the relationship between IO pressures (IOPs) and systemic hemodynamic pressures such as mean arterial pressure (MAP) and central venous pressures (CVP). ⋯ The relationship between IOP and MAP or CVP is variable by site, with the MAP and CVP tending to be estimated by the femur and sternum, respectively. The relationship to actively rising pressures is nonlinear and a hysteresis model is proposed to explain the phase change. Further experimentation is needed to refine the IOP relationship to the MAP and CVP and assess the potential of these measurements to provide clinically relevant information.