Medical engineering & physics
-
Owing to limited quantitative data related to the loadings (forces and pressures) acting upon finger joints, several clinical observations regarding mechanical risk factors of hand osteoarthritis remain misunderstood. To improve the knowledge of this pathology, the present study used musculoskeletal modelling to quantify the forces and pressures acting upon hand joints during two grasping tasks. Kinematic and grip force data were recorded during both a pinch and a power grip tasks. ⋯ When compared with the power grip task, the pinch grip task resulted in two to eight times higher joint loadings whereas the grip forces exerted on each finger were twice lower. For both tasks, joint forces and pressures increased along a disto-proximal direction for each finger. The quantitative dataset provided by the present hand model clarified two clinical observations about osteoarthritis development which were not fully understood, i.e., the strong risk associated to pinch grip tasks and the high frequency of thumb-base osteoarthritis.
-
Degeneration of the intervertebral disc, sometimes associated with low back pain and abnormal spinal motions, represents a major health issue with high costs. A non-invasive degeneration assessment via qualitative or quantitative MRI (magnetic resonance imaging) is possible, yet, no relation between mechanical properties and T2 maps of the intervertebral disc (IVD) has been considered, albeit T2 relaxation time values quantify the degree of degeneration. Therefore, MRI scans and mechanical tests were performed on 14 human lumbar intervertebral segments freed from posterior elements and all soft tissues excluding the IVD. ⋯ In addition to mean T2, the OTSU threshold of T2 (TOTSU), a robust and automatic histogram-based method that computes the optimal threshold maximizing the distinction of two classes of values, was calculated for anterior, posterior, left and right regions of each annulus fibrosus (AF). While mean T2 and degeneration schemes were not related to the IVDs' mechanical properties, TOTSU computed in the posterior AF correlated significantly with those classifications as well as with all stiffness values. TOTSU should therefore be included in future degeneration grading schemes.
-
The purpose of this study was to develop a new fixation technique for the treatment of periprosthetic fractures using intraprosthetic screw fixation. The goal was to biomechanically evaluate the increase in primary fixation stability compared to unicortical locked-screw plating. ⋯ Intraprosthetic screw anchorage with a special prosthesis drill enhances the primary stability in treating periprosthetic fractures by internal fixation.
-
Bone sawing simulators with force feedback represent a cost effective means of training orthopedic surgeons in various surgical procedures, such as total knee arthroplasty. To develop a machine with accurate haptic feedback, giving a sensation of both cutting force and rate of material removal, algorithms are required to forecast bone sawing forces based on user input. Presently, studies on forces generated while machining bone are not representative of the high cutting speeds and low depths of cut common to the bone sawing process. ⋯ The increase in thrust force with depth of cut was relatively linear, R(2)=0.80. Using a two factor, two level design of experiments approach, regression equations were developed to relate sawing forces to changes in blade speed and depth of cut. These equations can be used to predict forces in a haptic feedback model.
-
Thirty-one central neural blockade simulators have been implemented into clinical practice over the last thirty years either commercially or for research. This review aims to provide a detailed evaluation of why we need epidural and spinal simulators in the first instance and then draws comparisons between computer-based and manikin-based simulators. This review covers thirty-one simulators in total; sixteen of which are solely epidural simulators, nine are for epidural plus spinal or lumbar puncture simulation, and six, which are solely lumbar puncture simulators. ⋯ The purpose of this comparative review is to identify the direction for future epidural simulation by outlining necessary improvements to create the ideal epidural simulator. The weaknesses of existing simulators are discussed and their strengths identified so that these can be carried forward. This review aims to provide a foundation for the future creation of advanced simulators to enhance the training of epiduralists, enabling them to comprehensively practice epidural insertion in vitro before training on patients and ultimately reducing the potential risk of harm.