Medicina
-
Interstitial pregnancy (IP) is a type of ectopic pregnancy in which the embryo implants in the interstitial part of the Fallopian tube. It accounts for 2% of all ectopic pregnancies. Signs and symptoms appear later than the other forms of ectopic pregnancies because of its peculiar location. ⋯ The patient was discharged two days later and β-hCG serum levels became negative after 45 days. The advantages of fertility sparing should be weighted according to the patient's reproductive perspectives. Appropriate counseling is therefore key in managing the treatment of interstitial pregnancy.
-
Background and Objectives: Starting in early December 2019, the novel Coronavirus Disease (COVID-19) from infection with COVID-19 has caused a global pandemic. Many aspects of its pathogenesis and related clinical consequences are still unclear. Early diagnosis and dynamic monitoring of prognostic factors are essential to improve the ability to manage COVID-19 infection. ⋯ However, there is a lack of evidence-based guidelines which recommend vitamin C and D supplementation in patients with COVID-19, and results from high quality randomised controlled trials (RCTs) are inconsistent. Current investigations so far are mostly observational, and include a relatively small sample size which can lead to biased results. Large-scale multicentre studies are therefore needed.
-
Background and Objectives: Although reducing the radiation dose level is important during diagnostic computed tomography (CT) applications, effective image quality enhancement strategies are crucial to compensate for the degradation that is caused by a dose reduction. We performed this prospective study to quantify emphysema on ultra-low-dose CT images that were reconstructed using deep learning-based image reconstruction (DLIR) algorithms, and compared and evaluated the accuracies of DLIR algorithms versus standard-dose CT. Materials and Methods: A total of 32 patients were prospectively enrolled, and all underwent standard-dose and ultra-low-dose (120 kVp; CTDIvol < 0.7 mGy) chest CT scans at the same time in a single examination. ⋯ Results: The mean effective doses for standard-dose and ultra-low-dose CT scans were 3.43 ± 0.57 mSv and 0.39 ± 0.03 mSv, respectively (p < 0.001). The total lung volume and mean lung attenuation of five image datasets of ultra-low-dose CT scans, emphysema indices of ultra-low-dose CT scans reconstructed using ASIR-V 50 or DLIR-low, and the image noise of ultra-low-dose CT scans that were reconstructed using DLIR-low were not different from those of standard-dose CT scans. Conclusions: Ultra-low-dose CT images that were reconstructed using DLIR-low were found to be useful for emphysema quantification at a radiation dose of only 11% of that required for standard-dose CT.
-
Harlequin syndrome (HS) is a rare autonomic disorder. The causes and risk factors of the disease are not fully understood. Some cases of HS are associated with traumatic injuries, tumors, or vascular impairments of the head. ⋯ In some severe cases, symptomatic treatments could be needed. However, total symptomatic relief may not be achieved in many cases of HS. We therefore suggest an approach to comprehensive management of HS, which may lead to better long-term control of HS.
-
Randomized Controlled Trial
Effects of Positive End-Expiratory Pressure on Intraocular Pressure during One-Lung Ventilation in the Lateral Decubitus Position-A Prospective Randomized Trial.
Background and Objectives: The effect of positive end-expiratory pressure (PEEP) on intraocular pressure (IOP) is debatable. There have been no studies investigating the effects of PEEP on IOP during one-lung ventilation (OLV). We aimed to investigate the effects of PEEP on IOP in patients undergoing OLV for video-assisted thoracoscopic surgery (VATs). ⋯ The ratio of arterial oxygen partial pressure to fractional inspired oxygen was significantly higher in the PEEP group than in the ZEEP group at T4. Conclusions: Applying 6 cmH2O of PEEP did not increase IOP but enhanced dynamic compliance and oxygenation during OLV. These results suggest that 6 cmH2O of PEEP can be safely applied during OLV in LDP.