Background and Objectives: Non-invasive methods for evaluating liver fibrosis have been a crucial focus of clinical research. The aim of the current study is to assess the accuracy of serum alpha-fetoprotein (AFP) in determining the stage of liver fibrosis in patients with chronic hepatitis B (CHB) who are positive for HBeAg. Materials and Methods: The current study included a total of 276 HBeAg-positive CHB patients who underwent liver biopsy. ⋯ The results of the ROC analysis showed that serum AFP was an effective predictor of significant fibrosis, advanced fibrosis, and cirrhosis, with an area under the receiver operating characteristic curve (AUROC) of 0.773 (95% CI: 0.721-0.821), 0.889 (95% CI: 0.847-0.923), and 0.925 (95% CI: 0.887-0.953), respectively. These values are higher than those of the APRI and FIB-4. Conclusions: Serum AFP could serve as a valuable supplemental biomarker for determining the severity of liver fibrosis in HBeAg-positive patients with chronic hepatitis B.
-
Background and Objectives: A topic of greatinterest in the surgical field comprises cost and time reduction operative techniques with high efficiency rates. Thus, the aim of this paper is to evaluate whether a transection of the appendix using only a laparoscopic LigaSure™ device is feasible and, if so, which size of the laparoscopic device is optimal. Materials and Methods: Appendectomy specimens were sealed and cut using LigaSureTM V (5 mm) and LigaSure AtlasTM (10 mm) devices ex vivo. ⋯ The durability and eligibility of the 10 mm device were rated as very sufficient in 9 of 10 cases (1 perforation) in contrast to the 5 mm device, where the sealing in 9 of 10 cases was not sufficient (9 perforations). Conclusions: Using the 10 mm laparoscopic LigaSure™ device for the transection of the appendix seems to be feasible, safe and resistant to 300 mmHg bursting pressure. The 5 mm LigaSure™ instrument is inadequate to seal the appendix in humans.
-
Dietary supplements have been investigated for their impact on the periodontal apparatus (alveolar bone, mucosa, periodontal ligament, and cementum) and their hypothetical protective role against periodontitis. There remains a gap in the field in this area. Thus, the present study aims to examine the correlation between populations who report taking different dietary supplements and their relative periodontal health. ⋯ This study found a minimal association between the consumption of dietary supplements with periodontal health.
-
Review Meta Analysis
Fosfomycin for Antibiotic Prophylaxis in Men Undergoing a Transrectal Prostate Biopsy: A Systematic Review and Meta-Analysis.
Background and Objectives: To assess the effects of fosfomycin compared with other antibiotics as a prophylaxis for urinary tract infections (UTIs) in men undergoing transrectal prostate biopsies. Materials and Methods: We searched multiple databases and trial registries without publication language or status restrictions until 4 January 2022. Parallel-group randomized controlled trials (RCTs) and non-randomized studies (NRS) were included. ⋯ This difference corresponded to 16 fewer febrile UTIs per 1000 patients. Conclusions: Compared with fluoroquinolone, fosfomycin or fosfomycin and fluoroquinolone combined may have a similar prophylactic effect on UTIs after a transrectal prostate biopsy. Given the increasing fluoroquinolone resistance and its ease to use, fosfomycin may be a good option for antibiotic prophylaxis.
-
Background and Objectives: The health-related mobile applications (app) might assist in promoting inclusive health and tele-treatment, especially for the less severe diseases. In this paper, a study had been done to determine the app's reliability in terms of raters and the app's agreement with the Snellen chart. Materials and Methods: A cross-sectional sectional study was conducted between November 2019 and September 2020. ⋯ The kappa values for intra-rater and inter-rater were 0.85 and 0.75, respectively, while the app's reliability with the Snellen chart was 0.61. Conclusions: Vis-Screen was concluded to be valid and reliable for use as a screening tool for detecting individuals with visual impairment and blindness in the community. A valid and reliable portable vision screener like Vis-Screen will help expand the eye care feasibility while providing similar accuracy as the conventional charts in clinical practices.