Medicina
-
Systemic Lupus Erythematosus (SLE) is a systemic autoimmune disease that attacks various organ systems with a variety of clinical implications, ranging from mild skin and mucosal manifestations to severe central nervous system manifestations and death. Cases of SLE have been documented nearly two centuries ago when scholars used the terms 'erythema centrifugum' and 'seborrhea congestiva' to describe the discoid skin lesions and the butterfly or malar rash in SLE. ⋯ Various inflammatory mediators, cytokines and chemokines, as well as intra- and intercellular signaling pathways, are involved in the pathogenesis of SLE. In this review, we will discuss the molecular and cellular aspects of SLE pathogenesis, with a focus on how the immune system, genetics and the environment interact and trigger the various clinical manifestations of SLE.
-
Background and Objectives: The aim of this study is to investigate the femoral tunnel geometry (femoral tunsnel location, femoral graft bending angle, and femoral tunnel length) on three-dimensional (3D) computed tomography (CT) and graft inclination on magnetic resonance imaging (MRI) after anatomic anterior cruciate ligament (ACL) reconstruction using a flexible reamer system. Materials and Methods: A total of 60 patients who underwent anatomical ACL reconstruction (ACLR) using a flexible reamer system were retrospectively reviewed. One day after the ACLR procedure was performed, all patients underwent three-dimensional computed tomography (3D-CT) and magnetic resonance imaging (MRI). ⋯ The results of this study demonstrated that a comparable femoral graft bending angle and longer femoral tunnel length were observed compared with the reported outcomes from previous studies that used the rigid reamer system. Conclusions: ACLR using a flexible reamer system allowed for an anatomic femoral tunnel location and a comparable graft inclination to that of the native ACL. In addition, it achieved a tolerable femoral graft bending angle and femoral tunnel length.
-
Background and Objectives: There is a lack of data about the survival of patients after the implantation of sutureless relative to stented bioprostheses in middle-income settings. The objective of this study was to compare the survival of people with isolated severe aortic stenosis after the implantation of sutureless and stented bioprostheses in a tertiary referral center in Serbia. Materials and Methods: This retrospective cohort study included all people treated for isolated severe aortic stenosis with sutureless and stented bioprostheses from 1 January 2018 to 1 July 2021 at the Institute for Cardiovascular Diseases "Dedinje". ⋯ The multivariate Cox proportional hazard model suggested that being older, having a higher preoperative EuroScore II, having a stroke over the follow-up period and having valve-related complications were independently associated with all-cause mortality over a median of 2 years after the bioprosthesis implantation. Conclusions: This research conducted in a middle-income country supports previous findings in high-income countries regarding the survival of people with sutureless and stented valves. Survival after bioprosthesis implantation should be monitored long-term to ensure optimum postoperative outcomes.
-
Background and Objectives: In the field of orthopedic surgery, novel techniques of three-dimensional shape modeling using two-dimensional tomographic images are used for bone-shape measurements, preoperative planning in joint-replacement surgery, and postoperative evaluation. ZedView® (three-dimensional measurement instrument and preoperative-planning software) had previously been developed. Our group is also using ZedView® for preoperative planning and postoperative evaluation for more accurate implant placement and osteotomy. ⋯ Comparisons between measurements using the 3DMI and this software revealed that the mean error in length was <0.3 mm, and the error in angle was <0.25°. Study 2: In the bones adjusted to the retrocondylar plane with the 3DMI and this software, the average error in the distance from the planes to each marker was 0.43 (0.32-0.58) mm. Conclusion: This surgical planning software could measure the distance and angle between the centers of the markers with high accuracy; therefore, this is very useful for pre- and postoperative evaluation.
-
Background and Objectives: The current study aimed to better understand the changes in respiration that occur with aging in men and women to provide accurate recommendations for breathing exercises to improve health. Materials and Methods: A total of 610 healthy subjects, aged 20 to 59, participated in the study. They performed quiet breathing while wearing two respiration belts (Vernier, Beaverton, OR, USA) at the height of the navel and at the xiphoid process to record abdominal motion (AM) and thoracic motion (TM), respectively. ⋯ Women's respiratory movements did not change much with aging. The maximal inhalation movement became smaller with aging for men and women. Healthcare professionals should focus on improving thoracic mobility when addressing health concerns about aging.