Academic radiology
-
We compared contrast-enhanced T1-weighted magnetic resonance (MR) imaging of the brain using different types of data acquisition techniques: periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER, BLADE) imaging versus standard k-space sampling (conventional spin-echo pulse sequence) in the unsedated pediatric patient with focus on artifact reduction, overall image quality, and lesion detectability. ⋯ BLADE MR imaging at 1.5 T is applicable for central nervous system imaging of the unsedated pediatric patient, reduces motion and pulsation artifacts, and minimizes the need for sedation or general anesthesia without loss of relevant diagnostic information.
-
To assess computed tomographic (CT) signs that have been described in published studies for the diagnosis of appendicitis to identify independent findings that predict appendicitis. ⋯ Appendix diameter is the best single diagnostic criterion for appendicitis on CT scan. A cutoff between 8 and 9 mm provided the best balance of sensitivity/specificity in our study population, whereas a cutoff between 6 and 7 mm improved sensitivity at the expense of specificity. The presence of appendiceal enhancement provided additional diagnostic information, but other secondary signs of appendicitis did not improve diagnostic accuracy.
-
Treatment of brain neoplasms can greatly benefit from better delineation of bulk neoplasm boundary and the extent and degree of more subtle neoplastic infiltration. Magnetic resonance imaging (MRI) is the primary imaging modality for evaluation before and after therapy, typically combining conventional sequences with more advanced techniques such as perfusion-weighted imaging and diffusion tensor imaging (DTI). The purpose of this study is to quantify the multiparametric imaging profile of neoplasms by integrating structural MRI and DTI via statistical image analysis methods to potentially capture complex and subtle tissue characteristics that are not obvious from any individual image or parameter. ⋯ This approach has potential applications in treatment, aiding computer-assisted surgery by determining the spatial distributions of healthy and neoplastic tissue, as well as in identifying tissue that is relatively more prone to tumor recurrence.
-
The development of parallel magnetic resonance imaging has resulted in the frequent use of diffusion-weighted imaging (DWI) in clinical medicine, which usually involves the use of contrast medium. However, gadolinium (Gd) contrast medium may have some effect on DWI and the apparent diffusion coefficient (ADC). The present study was performed to determine whether the magnetic susceptibility of contrast medium alters the DWI signal and the value of ADC in some imaging techniques. ⋯ ADC was not influenced by the magnetic susceptibility of contrast medium. In addition, it was suggested that the ability of tumor detection may be reduced if STIR is used as fat suppression.
-
To establish the normal criterion of ascending aortic diameter (AAOD) measured by 64 multidetector computed tomography (MDCT) and electron beam computed tomography (EBT) based on gender and age. ⋯ The AAOD increases with age and male gender. Gender-specific and age-adjusted normal values for aortic diameters are necessary to differentiate pathologic atherosclerotic changes in the ascending aorta. Use of intraluminal or total aortic diameter values depends on the comparison study employed.