Investigative radiology
-
Investigative radiology · Oct 2016
Three-Dimensional CAIPIRINHA SPACE TSE for 5-Minute High-Resolution MRI of the Knee.
The aim of this study was to prospectively test the hypothesis that a 2-dimensional (2D) CAIPIRINHA (controlled aliasing in parallel imaging results in higher acceleration) sampling pattern facilitates 5-minute high spatial resolution 3-dimensional (3D) sampling perfection with application optimized contrast using different flip angle evolutions (SPACE) magnetic resonance imaging (MRI) of the knee with image quality similar or better than current 2D turbo spin echo (TSE) and 3D SPACE standards. ⋯ Three-dimensional SPACE with 2D CAIPIRINHA sampling pattern enables high-quality 3D TSE MRI of the knee at an acquisition time of 5 minutes and image quality, visibility of anatomic structures, SNR, and CNR similar to conventional 3D SPACE and 2D TSE, both of which require approximately 10-minute acquisition times.
-
Investigative radiology · Oct 2016
Systematic Evaluation of Amide Proton Chemical Exchange Saturation Transfer at 3 T: Effects of Protein Concentration, pH, and Acquisition Parameters.
The goal of this work was to systematically evaluate the reproducibility of amide proton transfer chemical exchange saturation transfer (APT-CEST) at 3 T and its signal dependence on pH, protein concentration, and acquisition parameters. An in vitro system based on bovine serum albumin (BSA) was used, and its limitations were tested by comparing it to in vivo measurements. The contribution of small endogenous metabolites on the APT-CEST signal at 3 T was also investigated. In addition, the reliability of different z-spectrum interpolations as well as the use of only a few frequency offset data points instead of a whole z-spectrum were tested. ⋯ Amide proton transfer-CEST imaging is a highly reproducible method in which absolute signal differences of approximately 0.5% are detectable in principle. For in vivo applications, Fourier or sSpline interpolations of z-spectra are preferable. Using reduced data sets delivers similar results but with increased variation and therefore decreased (pH/concentration) differentiation capability. Differentiation capability increases with increases in the saturation duration and power level. The results from the in vitro BSA system cannot be directly transferred to the in vivo situation due to different chemical environments resulting in, for example, higher asymmetric macromolecular cMT effects in vivo. Amine signals from small molecules are unlikely to contribute to APT-CEST at 3 T (except for creatine); however, signals can be enhanced by using short saturation times and higher power levels.
-
Investigative radiology · Sep 2016
Comparative StudyMorphological and Quantitative 7 T MRI of Hip Cartilage Transplants in Comparison to 3 T-Initial Experiences.
The aims of this study were to evaluate morphological and quantitative 7 T magnetic resonance imaging (MRI) hip sequences in patients after acetabular cartilage transplantation and to compare image quality with 3 T MRI. ⋯ This study shows the feasibility of morphological and quantitative 7 T hip MRI in patients after acetabular cartilage transplantation and its predominant superiority regarding image quality, assessment of cartilage transplants, and contrast over 3 T MRI. To compare relaxation times between the field strengths, the calculation of intraindividual ratios is recommended.
-
Investigative radiology · Jun 2016
Six-Fold Acceleration of High-Spatial Resolution 3D SPACE MRI of the Knee Through Incoherent k-Space Undersampling and Iterative Reconstruction-First Experience.
The aim of this study was to prospectively test the hypothesis that 6-fold acceleration of a 3-dimensional (3D) turbo spin echo (TSE) magnetic resonance imaging (MRI) pulse sequence with k-space undersampling and iterative reconstruction is feasible for fast high spatial resolution MRI of the knee, while yielding similar image quality and diagnostic performance when compared with a conventional 2-dimensional (2D) TSE MRI standard. ⋯ We demonstrate the successful clinical implementation of 3D TSE MRI with incoherent k-space undersampling and iterative reconstruction for 6-fold accelerated high spatial resolution isotropic 3D MRI data acquisition. Our preliminary assessments suggest similar image quality and diagnostic performance of a comprehensive 10-minute 3D TSE MRI prototype protocol and 20-minute TSE MRI standard protocol.
-
Investigative radiology · May 2016
Integrated Shimming Improves Lesion Detection in Whole-Body Diffusion-Weighted Examinations of Patients With Plasma Disorder at 3 T.
The purpose of this study was to evaluate the feasibility of using integrated slice-by-slice shimming (iShim) for improving the image quality of whole-body diffusion-weighted imaging (WBDWI) in patients with plasma disorder at 3 T by comparing to WBDWI using a conventional shimming (3-dimensional [3D] shim) adjustment of each body station. ⋯ The iShim technique is an effective method to reduce the negative impact of susceptibility effects at 3 T on whole-body diffusion imaging, as supported by the apparent improvement in signal integrity and spatial alignment, as well as improved SNR in the neck region. Compared with the 3D shim technique, the iShim technique showed improved conspicuous lesion findings in the neck region.