Blood pressure monitoring
-
Blood pressure monitoring · Oct 2007
Clinical TrialAccuracy of the HoMedics BPA-300, a home blood pressure monitor using the auscultatory method.
To determine whether the HoMedics Model BPA-300 meets American Association for the Advancement of Medical Instrumentation (AAMI) accuracy standards. ⋯ The HoMedics Model BPA-300 meets AAMI accuracy standards using methods 1 and 2.
-
Blood pressure monitoring · Oct 2007
Comparative StudyEffect of the shapes of the oscillometric pulse amplitude envelopes and their characteristic ratios on the differences between auscultatory and oscillometric blood pressure measurements.
Oscillometric noninvasive blood pressure (NIBP) devices determine pressure by analysing the oscillometric waveform using empirical algorithms. Many algorithms analyse the waveform by calculating the systolic and diastolic characteristic ratios, which are the amplitudes of the oscillometric pulses in the cuff at, respectively, the systolic and diastolic pressures, divided by the peak pulse amplitude. A database of oscillometric waveforms was used to study the influences of the characteristic ratios on the differences between auscultatory and oscillometric measurements. ⋯ The systolic and diastolic paired oscillometric-auscultatory pressure differences varied with their corresponding characteristic ratios. Good agreement (within 5 mmHg) between the oscillometric and auscultatory pressures occurred for oscillometric pulse amplitude envelopes with specific ranges of characteristic ratios, but the ranges were different for the two devices. Further work is required to classify the different envelope shapes, comparing them with patient conditions, to determine if a clearer understanding of the different waveform shapes would improve the accuracy of oscillometric measurements.
-
Blood pressure monitoring · Oct 2007
Clinical TrialEvaluation of the SCHILLER BR-102 plus noninvasive ambulatory blood pressure monitor according to the International Protocol introduced by the Working Group on Blood Pressure Monitoring of the European Society of Hypertension.
To evaluate the SCHILLER BR-102 plus (Schiller AG, Baar, Switzerland) noninvasive ambulatory blood pressure recorder according to the International Protocol for validation of blood pressure measuring devices in adults introduced by the Working Group on Blood Pressure Monitoring of the European Society of Hypertension. ⋯ On the basis of these results, the SCHILLER BR-102 plus can be recommended for ambulatory blood pressure measurement in clinical practice using both auscultatory and oscillometric modes.
-
Blood pressure monitoring · Aug 2007
Comparative StudyValidation of the Omron M6 (HEM-7001-E) upper-arm blood pressure measuring device according to the International Protocol in adults and obese adults.
Electronic blood pressure (BP) measurement devices are the preferred choice of patients owing to their user-friendly nature; however, there is a requirement to investigate the accuracy and reliability of these devices. The objective of this study is to evaluate the accuracy of the Omron M6 upper-arm BP device against the mercury sphygmomanometer in adults and obese adults according to the International Protocol criteria. ⋯ It was concluded that the Omron M6 device, which measures BP at the upper arm, was deemed to be in accordance with the International Protocol criteria and can be recommended for use by adults and obese adults.
-
Blood pressure monitoring · Aug 2007
Comparative StudyValidation of the Omron M5-I, R5-I and HEM-907 automated blood pressure monitors in elderly individuals according to the International Protocol of the European Society of Hypertension.
This study aimed at verifying the accuracy of three automated electronic oscillometric blood pressure measuring devices, namely Omron M5-I (home use upper arm monitor), R5-I (home use wrist monitor) and HEM-907 (professional use upper arm monitor) according to the European Society of Hypertension International Protocol in elderly individuals. ⋯ According to the results of the validation study based on the European Society of Hypertension International Protocol the Omron M5-I, R5-I, and HEM-907 may be recommended for clinical use in elderly individuals, without atrial fibrillation or frequent ectopic beats.