Prehospital emergency care : official journal of the National Association of EMS Physicians and the National Association of State EMS Directors
-
Cardiac arrest in pregnancy is rare. It has a reported incidence of approximately 1 in 30000 pregnancies worldwide and occurs prehospitally with rates of around 3 in every 100000 live births within the developed world. The management of maternal cardiac arrest is complicated by the anatomical and physiological changes of pregnancy, its rarity and clinician unfamiliarity. ⋯ Although rarely reported in the field it is possible to successfully perform the procedure. This report details the emergent prehospital treatment of a 41-year-old woman pregnant with her first child of 30 weeks gestation. It describes a case of maternal cardiac arrest, her resuscitation and the undertaking of a prehospital perimortem cesarean section resulting in a neurologically intact infant survivor.
-
Background: Prehospital intubation success is routinely treated as a dichotomous outcome based on an endotracheal tube passing through vocal cords regardless of number of attempts or occurrence of hypoxia, or hypotension, which are associated with worse outcomes. We explore patient, provider, and procedure-related variables associated with successful definitive airway sans hypoxia/hypotension on first attempt (DASH-1A) in traumatically injured subjects undergoing endotracheal intubation at the scene of injury by a helicopter EMS system. Methods: This single-center retrospective chart review included patients with traumatic injuries and at least one attempted intubation by helicopter EMS at the scene of injury. ⋯ Factors significantly associated with successful DASH-1A were no ground EMS intubation attempt prior to arrival [aOR 2.2 (CI 1.0-4.9)], lack of airway secretions/blood [1.9 (1.0-3.4)], Cormack-Lehane Score of I and II [12.3 (4.5-33.2) & 3.2 (1.2-9.1), respectively], and bougie use [5.4 (1.8-15.8)]. For endotracheal tube passing only, the following were significantly associated with first pass success: grade of view I and II [aORs 87.3 (CI 25.8-295.7) & 6.8 (2.3-19.5), respectively], lack of secretions/blood [4.9 (2.1-11.2), bougie use [7.8 (2.3-26.3)], direct laryngoscopy [5.1 (1.5-17.0)] and not using apneic oxygenation through a nasal cannula [2.5 (1.1-5.6)]. Conclusion: In our helicopter EMS system, successful endotracheal intubation on the first attempt and without an episode of hypoxia was associated with no ground EMS intubation attempt prior to flight crew arrival, lack of airway secretions/blood, Cormack-Lehane Score, and bougie use.
-
Observational Study
Prevalence and predictors of post-intubation hypotension in prehospital trauma care.
Prehospital care of severe trauma patients often involves endotracheal intubation (ETI), which has complications. The frequency and predictors of post-ETI hypotension and cardiac arrest are not well defined in this population. We sought to derive and validate a scoring system that predicts post-ETI hypotension in prehospital patients and to describe the impact of hypotension on outcome. ⋯ Applying our system, 890 (33%) derivation patients and 550 (37%) validation patients were higher risk for post-ETI adverse outcomes. Of these, 21% and 33% respectively experienced post-ETI hypotension and 6% and 4%, respectively suffered post-ETI cardiac arrest. Patients at high risk for post-ETI hypotension or arrest are common and identifiable in prehospital trauma care.
-
Case Reports
Prehospital Laryngeal Tube Airway Device Placement Resulting in Hypopharyngeal Perforation: A Case Report.
A 26-year-old female patient presented in cardiac arrest from presumed opioid overdose. An Ambu King LTS-D laryngeal device was placed by EMS providers for airway management during the resuscitation. There was no documented difficulty with placement and breath sounds and waveform capnography were consistent with appropriate placement. ⋯ The case report describes a rare, yet potentially life-threatening, complication of laryngeal tube airway device placement- hypopharyngeal injury. If unrecognized, this injury could lead to serious complications. Providers should be aware of the common and uncommon injuries that are associated with prehospital laryngeal tube airway device placement.
-
Observational Study
Comparing the Accuracy of Mass Casualty Triage Systems When Used in an Adult Population.
Objective: To use a previously published criterion standard to compare the accuracy of 4 different mass casualty triage systems (Sort, Assess, Lifesaving Interventions, Treatment/Transport [SALT], Simple Triage and Rapid Treatment [START], Triage Sieve, and CareFlight) when used in an emergency department-based adult population. Methods: We performed a prospective, observational study of a convenience sample of adults aged 18 years or older presenting to a single tertiary care hospital emergency department. A co-investigator with prior emergency medical services (EMS) experience observed each subject's initial triage in the emergency department and recorded all data points necessary to assign a triage category using each of the 4 mass casualty triage systems being studied. ⋯ SALT had the highest over-triage rate (22%; 95% CI 14-29) compared to START (7%; 95% CI 3-12), CareFlight (6%; 95% CI 2-11) and TriageSieve (6%; 95% CI 2-11). Conclusion: We found that SALT triage most often correctly triaged adult emergency department patients when compared to a previously published criterion standard. While there are no target under- and over-triage rates that have been published for mass casualty triage, all 4 systems had relatively high rates of under-triage.