Health technology assessment : HTA
-
Health Technol Assess · Dec 2012
ReviewWhat is the value of routinely testing full blood count, electrolytes and urea, and pulmonary function tests before elective surgery in patients with no apparent clinical indication and in subgroups of patients with common comorbidities: a systematic review of the clinical and cost-effective literature.
The evidence base which supported the National Institute for Health and Clinical Excellence (NICE) published Clinical Guideline 3 was limited and 50% was graded as amber. However, the use of tests as part of pre-operative work-up remains a low-cost but high-volume activity within the NHS, with substantial resource implications. The objective of this study was to identify, evaluate and synthesise the published evidence on the clinical effectiveness and cost-effectiveness of the routine use of three tests, full blood counts (FBCs), urea and electrolytes tests (U&Es) and pulmonary function tests, in the pre-operative work-up of otherwise healthy patients undergoing minor or intermediate surgery in the NHS. ⋯ The National Institute for Health Research Health Technology Assessment programme.
-
Health Technol Assess · Nov 2012
Randomized Controlled Trial Multicenter StudyTypes of urethral catheter for reducing symptomatic urinary tract infections in hospitalised adults requiring short-term catheterisation: multicentre randomised controlled trial and economic evaluation of antimicrobial- and antiseptic-impregnated urethral catheters (the CATHETER trial).
Catheter-associated urinary tract infection (CAUTI) is a major preventable cause of harm for patients in hospital and incurs significant costs for health-care providers such as the UK NHS. Many preventative strategies and measures have been introduced to minimise CAUTI risk, including the use of antimicrobial catheters. However, there is considerable uncertainty regarding their usefulness in terms of reducing symptomatic CAUTI, and whether or not they are cost-effective. ⋯ The trial estimate of clinical effectiveness for nitrofurazone-impregnated catheters was less than the pre-specified minimum absolute risk difference that we considered important (-3.3%), and the surrounding CI included zero, indicating that any reduction in catheter-associated UTI was uncertain. Economic analysis, although associated with uncertainty, suggested that nitrofurazone-impregnated catheters may be cost-effective for the NHS. The trial ruled out the possibility that silver alloy-coated catheters might reach the pre-set degree of clinical effectiveness and that their use was unlikely to be cost-effective. These findings should be considered by patients, clinicians and health-care policy-makers to determine whether or not a change in practice is worthwhile. Future research should be aimed at determining the minimum clinically important difference in terms of CAUTI prevention in comparative trials, and to identify reliable methods which can detect the impact of the intervention on quality of life and other drivers of cost, when the intervention is a subsidiary part of overall treatment plans.
-
Health Technol Assess · Sep 2012
ReviewInfluence of reported study design characteristics on intervention effect estimates from randomised controlled trials: combined analysis of meta-epidemiological studies.
The design of randomised controlled trials (RCTs) should incorporate characteristics (such as concealment of randomised allocation and blinding of participants and personnel) that avoid biases resulting from lack of comparability of the intervention and control groups. Empirical evidence suggests that the absence of such characteristics leads to biased intervention effect estimates, but the findings of different studies are not consistent. ⋯ National Institute for Health Research Health Technology Assessment programme.
-
Health Technol Assess · Sep 2012
Randomized Controlled TrialA pilot randomised controlled trial in intensive care patients comparing 7 days' treatment with empirical antibiotics with 2 days' treatment for hospital-acquired infection of unknown origin.
Management of cardiac intensive care unit (ICU) sepsis is complicated by the high incidence of systemic inflammatory response syndrome, which mimics sepsis but without an infective cause. This pilot randomised trial investigated whether or not, in the ICU, 48 hours of broad-spectrum antibiotic treatment was adequate to safely treat suspected sepsis of unknown and unproven origin and also the predictive power of newer biomarkers of sepsis. ⋯ Data from this pilot study suggest that there could be significant benefits of reducing broad-spectrum antibiotic use in the ICU without it undermining patient safety, with a potential cost saving in our unit of over £100,000 per year. Evidence from this pilot trial is not definitive but warrants further investigation using a large randomised controlled trial.
-
Health Technol Assess · Jul 2012
ReviewThe measurement of patients' expectations for health care: a review and psychometric testing of a measure of patients' expectations.
There is recognition of the importance of measuring patients' experiences, expectations and satisfaction. ⋯ The National Institute for Health Research Health Technology Assessment programme and the National Co-ordinating Centre for Research Methodology (NCCRM).