Computer aided surgery : official journal of the International Society for Computer Aided Surgery
-
Comput. Aided Surg. · Jan 2000
Is the head position during preoperative image data acquisition essential for the accuracy of navigated brain tumor surgery?
To analyze the influence of head positioning during preoperative image data acquisition on intraoperative accuracy of modern neuronavigation systems. ⋯ The data suggest that the positioning of the patient's head during preoperative imaging plays no relevant role in intraoperative accuracy of neuronavigation. However, further studies and a larger number of patients with various pathologies in different regions of the brain are necessary to obtain a better understanding of the problem of brain shift in neuronavigation due to patient positioning alone, and to avoid procedure-related operative morbidity.
-
Comput. Aided Surg. · Jan 2000
A data fusion environment for multimodal and multi-informational neuronavigation.
Part of the planning and performance of neurosurgery consists of determining target areas, areas to be avoided, landmark areas, and trajectories, all of which are components of the surgical script. Nowadays, neurosurgeons have access to multimodal medical imaging to support the definition of the surgical script. The purpose of this paper is to present a software environment developed by the authors that allows full multimodal and multi-informational planning as well as neuronavigation for epilepsy and tumor surgery. ⋯ In this short evaluation, the ability to access preoperative multi-functional and anatomical data within the neuronavigation system was a valuable support for the surgical procedure.
-
Comput. Aided Surg. · Jan 2000
A software system for interventional magnetic resonance image-guided prostate brachytherapy.
Current prostatic brachytherapy implant procedures use ultrasound imaging for geometric guidance during surgery, with pre-surgical planning based on ultrasound images and post-surgical dosimetry based on computed tomography (CT). This procedure suffers from the poor soft-tissue contrast of ultrasound and CT and problems inherent in the repositioning of the patient at surgery. We have designed and implemented an integrated real-time imaging and treatment-planning software system that combines the superior soft-tissue contrast of magnetic resonance (MR) images with the real-time acquisition of those images for localization, verification, and dosimetric purposes. The system permits the surgeon and patient to complete all phases of treatment in one setting. ⋯ The system is highly interactive, and has great flexibility in its design, maintainability, and clinical practice. The system provides an efficient model to support the surgical procedure. The system significantly improves the diagnostic information provided to the clinician and the treatment planner and the geometric accuracy of the surgical procedure compared to ultrasound procedures. The system allows excellent critical structure sparing, both through interactive placement of the catheters with high geometric accuracy and through the definition of the actual sub-prostatic volumes possible with MR.
-
Comput. Aided Surg. · Jan 2000
Ultrasound-based stereotactic guidance in prostate cancer--quantification of organ motion and set-up errors in external beam radiation therapy.
A mobile transabdominal ultrasound-based targeting system (BAT(R)) has been developed which can stereotactically localize the position of the prostate each treatment day and directly integrate this information into the treatment planning system. Daily target verification facilitates a marked reduction in planning treatment margins by correcting potential organ-motion and set-up errors. Previous studies have been performed to establish the precision of ultrasound localization. This report quantifies the magnitude of the patient isocenter shift parameters encountered during clinical implementation of this system. ⋯ Organ motion and set-up uncertainties limit optimization of 3D treatment planning by expanding the width of PTV margins required to ensure target coverage. Transabdominal ultrasound-based stereotactic guidance is a safe and direct method for correcting patient positioning. Our experience with the BAT system in a large cohort of prostate cancer patients revealed that substantial daily isocenter corrections were encountered in a large percentage of cases. This data would suggest that daily clinical isocenter misalignments are greater than would be expected from published data on organ motion and set-up variations encountered in the study setting.
-
Comput. Aided Surg. · Jan 1998
Development of an endoscopic navigation system based on digital image processing.
We developed a new system to couple the endoscope to an optical position measurement system (OPMS) so that the image frames from the endoscope camera can be labeled with the accurate endoscopic position. This OPMS is part of the EasyGuide Neuro navigation system, which is used for microsurgery and neuroendoscopy. Using standard camera calibration techniques and a newly developed system calibration, any 3-dimensional (3-D) world point can be mapped onto the view from the endoscope. ⋯ Several modules, including a new motion alarm system and the "tracking" and "virtual map" modules, were tested in a human cadaveric model using the frontal and occipital approaches. A failure rate of 8.6% was experienced during testing of the first version of the software, but the second version was 100% successful. Thus, an endoscopic navigation system based on digital image processing has been developed that could be a revolutionary advance in image-guided surgery.