British journal of anaesthesia
-
Patients with inherited cardiac channel disorders are at high risk of perioperative lethal arrhythmias. Preoperative control of symptoms and a multidisciplinary approach are required for a well-planned management. Good haemodynamic monitoring, adequate anaesthesia and analgesia, perioperative maintenance of normocarbia, normothermia, and normovolaemia are important. ⋯ Propofol and remifentanil are probably safe, while halothane and pancuronium are contraindicated. Regional anaesthesia, without epinephrine, is relatively safe. In suspicious cardiac deaths, postmortem examination and familial screening are recommended.
-
Multiple studies have shown that cerebral tissue oxygen saturation (Sct(O(2))) is decreased after phenylephrine treatment. We hypothesized that the negative impact of phenylephrine administration on Sct(O(2)) is affected by arterial blood carbon dioxide partial pressure (Pa(CO(2))) because CO(2) is a powerful modulator of cerebrovascular tone. ⋯ The negative impact of phenylephrine treatment on Sct(O(2)) and CBV is intensified during hypocapnia while blunted during hypercapnia.
-
The STOP-Bang questionnaire is used to screen patients for obstructive sleep apnoea (OSA). We evaluated the association between STOP-Bang scores and the probability of OSA. ⋯ In the surgical population, a STOP-Bang score of 5-8 identified patients with high probability of moderate/severe OSA. The STOP-Bang score can help the healthcare team to stratify patients for unrecognized OSA, practice perioperative precautions, or triage patients for diagnosis and treatment.
-
Draw-over anaesthesia is widely used throughout the developing world, in disaster areas and in military anaesthesia when the supply of pressurized oxygen is unreliable. To date, no draw-over vaporizer has been able to deliver sufficient concentrations of sevoflurane for use in inhalation induction of anaesthesia. A laboratory study to assess the performance of a new vaporizer (DDV2) to deliver sevoflurane in a wide range of situations is described. ⋯ The modifications to the DDV2 allow stable concentrations of sevoflurane to be delivered in draw-over and continuous flow modes over a range of temperatures. With continuous flow, concentrations of sevoflurane sufficient for induction of anaesthesia can be achieved.
-
Comparative Study
Pumpless arterio-venous extracorporeal lung assist compared with veno-venous extracorporeal membrane oxygenation during experimental lung injury.
Extracorporeal lung support is effective to prevent hypoxaemia and excessive hypercapnia with respiratory acidosis in acute respiratory distress syndrome. Miniaturized veno-venous extracorporeal membrane oxygenation (mECMO) and arterio-venous pumpless extracorporeal lung assist (pECLA) were compared for respiratory and haemodynamic response and extracorporeal gas exchange and device characteristics. ⋯ Both devices have the potential to unload the lungs from gas transfer sufficiently to facilitate lung-protective ventilation. Although technically less complex, oxygen uptake and carbon dioxide removal are limited in pECLA, and cardiac work was increased. mECMO overcomes these limitations and might provide better cardiopulmonary protection.