British journal of anaesthesia
-
Anaemic cardiac surgery patients are at greater risk of intraoperative red blood cell transfusion. This study questions the application of the World Health Organization population-based anaemia thresholds (haemoglobin <120 g L-1 in non-pregnant females and <130 g L-1 in males) as appropriate preoperative optimisation targets for cardiac surgery. ⋯ The World Health Organization female anaemia threshold of haemoglobin <120 g L-1 disproportionately disadvantages female cardiac surgery patients. A preoperative haemoglobin concentration ≥130 g L-1 in adult cardiac surgery patients would minimise their overall probability of intraoperative red blood cell transfusion to <15%.
-
Use of sodium-glucose transporter-2 (SGLT2) inhibitors has dramatically increased over the past decade. This medication class predisposes patients to euglycaemic diabetic ketoacidosis, particularly during times of physiologic stress, including fasting and surgery. Beyond case reports and series, a systematic description of perioperative metabolic effects of SGLT2 inhibitors is lacking. ⋯ These findings provide the first evidence that an anion gap acidosis, likely from ketoacids, develops in all patients who do not hold SGLT2 inhibitors before surgery rather than in an idiosyncratic few. If an SGLT2 inhibitor is unable to be stopped, postoperative monitoring of anion gap and serum ketones can help detect clinically significant euglycaemic diabetic ketoacidosis, particularly in those undergoing emergency surgery.
-
A recent systematic review and meta-analysis by Wang and colleagues in the British Journal of Anaesthesia calls into question the concept that perioperative benzodiazepine administration is associated with development of postoperative delirium in older individuals after anaesthesia and surgery. This editorial focuses on potential bias within the systematic review and addresses major concerns surrounding benzodiazepine use in the older perioperative population.
-
Comment Letter Randomized Controlled Trial
Serratus anterior and pectoralis plane blocks for robotically assisted mitral valve repair: a randomised clinical trial. Comment on Br J Anaesth 2023; 130: 786-94.
-
Auditory roughness in medical alarm sounds is an important design attribute, and has been shown to impact user performance and perception. While roughness can assist in decreased signal-to-noise ratios (perceived loudness) and communicate urgency, it might also impact patient recovery. Therefore, considerations of neuroscience correlates, music theory, and patient impact are critical aspects to investigate in order to optimise alarm design.