Critical care : the official journal of the Critical Care Forum
-
Use of terlipressin in septic shock relies on a series of European studies resulting in a better knowledge of this vasopressive agent. Additional studies demonstrate that this agent appears to have attractive properties when administered properly. In comparison to prior reports, continuous infusion of low-dose terlipressin seems superior when administered to septic animals. For the first time in humans, Morelli and colleagues compared this mode of administration with other vasopressors.
-
Fluid responsiveness prediction is difficult in spontaneously breathing patients. Because the swings in intrathoracic pressure are minor during spontaneous breathing, dynamic parameters like pulse pressure variation (PPV) and systolic pressure variation (SPV) are usually small. We hypothesized that during spontaneous breathing, inspiratory and/or expiratory resistors could induce high arterial pressure variations at hypovolemia and low variations at normovolemia and hypervolemia. Furthermore, we hypothesized that SPV and PPV could predict fluid responsiveness under these conditions. ⋯ Inspiratory and/or expiratory threshold resistors magnified SPV and PPV in spontaneously breathing pigs during hypovolemia. Using the expiratory resistor SPV and PPV predicted fluid responsiveness with good sensitivity and specificity.
-
Checklists are common tools used in many industries. Unfortunately, their adoption in the field of medicine has been limited to equipment operations or part of specific algorithms. Yet they have tremendous potential to improve patient outcomes by democratizing knowledge and helping ensure that all patients receive evidence-based best practices and safe high-quality care. ⋯ In this article, we explore some of the principles and possible strategies to further develop and encourage the implementation of checklists into medical practice. We describe different types of checklists using examples and explore the benefits they offer to improve care. We suggest methods to create checklists and offer suggestions for how we might apply them, using some examples from our own experience, and finally, offer some possible directions for future research.
-
Multicenter Study Comparative Study
Characteristics and outcomes of cancer patients in European ICUs.
Increasing numbers of cancer patients are being admitted to the intensive care unit (ICU), either for cancer-related complications or treatment-associated side effects, yet there are relatively few data concerning the epidemiology and prognosis of cancer patients admitted to general ICUs. The aim of this study was to assess the characteristics of critically ill cancer patients, and to evaluate their prognosis. ⋯ In this large European study, patients with cancer were more often admitted to the ICU for sepsis and respiratory complications than other ICU patients. Overall, the outcome of patients with solid cancer was similar to that of ICU patients without cancer, whereas patients with haematological cancer had a worse outcome.
-
Bland-Altman analysis is used for assessing agreement between two measurements of the same clinical variable. In the field of cardiac output monitoring, its results, in terms of bias and limits of agreement, are often difficult to interpret, leading clinicians to use a cutoff of 30% in the percentage error in order to decide whether a new technique may be considered a good alternative. This percentage error of +/- 30% arises from the assumption that the commonly used reference technique, intermittent thermodilution, has a precision of +/- 20% or less. ⋯ In a worked example in this paper, we discuss the limitations of this approach, in particular in regard to the situation in which the reference technique may be either more or less precise than would normally be expected. This can lead to inappropriate conclusions being drawn from data acquired in validation studies of new monitoring technologies. We conclude that it is not acceptable to present comparison studies quoting percentage error as an acceptability criteria without reporting the precision of the reference technique.