Critical care : the official journal of the Critical Care Forum
-
Potential benefits of subglottic secretion suction for preventing ventilator-associated pneumonia (VAP) are not fully understood. ⋯ Subglottic secretion suction decreased VAP incidence and duration of mechanical ventilation and delayed VAP onset. However, subglottic secretion suction did not reduce mortality and length of ICU stay. Subglottic secretion suction is recommended for preventing VAP and for reducing ventilation length, especially in the population at high risk of early onset VAP.
-
Ventilator-associated pneumonia (VAP) is the most frequent intensive care unit (ICU)-acquired infection that is independently associated with mortality. Accurate diagnosis and timely treatment have been shown to improve the prognosis of VAP. Chest X-ray or computed tomography imaging are used for conventional assessment of VAP, but these methods are impractical for real-time measurement in critical patients. ⋯ Traditionally, LUS has seemed unsuitable for the detection of lung parenchyma owing to the high acoustic impedance of air; however, the fact that the reflection and reverberation in the detection region of the ultrasound reflect the underlying pathology of lung diseases has led to the increased use of ultrasound imaging as a standard of care supported by evidence-based and expert consensus in the ICU. Considering that any type of pneumonia causes air volume changes in the lungs, accumulating evidence has shown that LUS effectively measures the presence of VAP as well as dynamic changes in VAP. This review offers evidence for ultrasound as a noninvasive, easily repeatable, and bedside means to assess VAP; in addition, it establishes a protocol for qualitative and quantitative monitoring of VAP.
-
Randomized Controlled Trial
Spontaneous breathing trial and post-extubation work of breathing in morbidly obese critically ill patients.
Predicting whether an obese critically ill patient can be successfully extubated may be specially challenging. Several weaning tests have been described but no physiological study has evaluated the weaning test that would best reflect the post-extubation inspiratory effort. ⋯ In obese patients, inspiratory effort measured during weaning tests with either a T-piece or a PSV 0 and PEEP 0 was not different to post-extubation inspiratory effort. In contrast, weaning tests with positive pressure overestimated post-extubation inspiratory effort.
-
The present study was designed to (1) establish current sedation practice in UK critical care to inform evidence synthesis and potential future primary research and (2) to compare practice reported via a survey with actual practice assessed in a point prevalence study (PPS). ⋯ Clinical practice reported in the national survey did not accurately reflect actual clinical practice at the patient level observed in the PPS. Employing a mixed methods approach provided a more complete picture of sedation practice in terms of breadth and depth of information.