Critical care : the official journal of the Critical Care Forum
-
Additional biomarkers in sepsis are needed to tackle the challenges of determining prognosis and optimizing selection of high-risk patients for application of therapy. In the present study, conducted in a cohort of medical intensive care unit patients, our aim was to compare the prognostic value of mid-regional pro-atrial natriuretic peptide (ANP) levels with those of other biomarkers and physiological scores. ⋯ Pro-ANP appears to be a valuable tool for individual risk assessment in sepsis patients and for stratification of high-risk patients in future intervention trials. Further studies are needed to validate our results.
-
Stridor is one of the most frequent causes of early extubation failure. The cuff-leak test may help to identify patients at risk to develop post-extubation laryngeal edema. However the discrimination power of the cuff-leak test is highly variable and can be use, at best, to detect patients at risk to develop edema but should not be used to postpone extubation as tracheal extubation can still be successful in many patients with a positive test. In this editorial, the author discuss the factors influencing the leak and hence its predictive value.
-
Because they share one pathognomonic sign (major hyperthermia), classic or environmental heatstroke and malignant hyperthermia have often been confronted from the therapeutic point of view. As expected and according to major physiopathological discrepancies between both syndromes, analysis of published data does not support effectiveness of dantrolene in heatstroke despite its significant reduction in mortality in malignant hyperthermia. If cooling methods still represent the cornerstone of the heatstroke therapeutic approach, the magnitude of heat-related deaths and the morbidity associated with the August 2003 French heatwave have highlighted the need for more ambitious methods of treatment.
-
The cuff-leak test has been proposed as a simple method to predict the occurrence of post-extubation stridor. The test is performed by cuff deflation and measuring the expired tidal volume a few breaths later (VT). The leak is calculated as the difference between VT with and without a deflated cuff. However, because the cuff remains deflated throughout the respiratory cycle a volume of gas may also leak during inspiration and therefore this method (conventional) measures the total leak consisting of an inspiratory and expiratory component. The aims of this physiological study were, first, to examine the effects of various variables on total leak and, second, to compare the total leak with that obtained when the inspiratory component was eliminated, leaving only the expiratory leak. ⋯ We conclude that the cross-sectional area around the endotracheal tube is not the only determinant of the cuff-leak test. System compliance and inspiratory flow significantly affect the test, mainly through an effect on the inspiratory component of the total leak. The expiratory component is slightly influenced by respiratory system resistance.