Journal of clinical monitoring and computing
-
J Clin Monit Comput · Dec 2014
Evaluation of a computer program for non-invasive determination of pulmonary shunt and ventilation-perfusion mismatch.
We describe a three-compartment model (shunt and two perfused compartments) to analyse the relationship between inspired oxygen (FIO2) and arterial oxygen saturation (SaO2) in terms of pulmonary shunt and ventilation-perfusion ratio (VA/Q). The program was tested using 24 exact datasets, each with six pairs of FIO2 and SaO2 data points with known VA/Q and shunt, generated by a complex calculator of gas exchange. Additional datasets were created by adding noise and rounding the exact sets, and by reducing the number of data points per dataset. ⋯ It is probably advantageous to correct for foetal haemoglobin in neonatal datasets. Analysis of FIO2 versus SaO2 datasets using a three compartment model provides accurate estimates of shunt and VA/Q when arterio-venous difference in oxygen content is known. The estimates may have value as objective measures of gas exchange, and as a visual guide for oxygen therapy.
-
J Clin Monit Comput · Dec 2014
Clinical TrialNon-invasive cardiac output evaluation in postoperative cardiac surgery patients, using a new prolonged expiration-based technique.
The gold standard methods to measure cardiac output (CO) are invasive and expose the patient to high risks of various complications. The aim of this study is to assess an innovative non-invasive method for CO monitoring in mechanically ventilated patients after cardiac surgery and its agreement with values obtained by thermodilution technique. Continuous monitoring of respiratory gas concentrations and airflow allows the estimation of CO through a newly developed algorithm derived from a modified version of the Fick equation. ⋯ COK shows a mean percentage error of 34 %. In stable mechanically ventilated patients, undergone cardiac surgery, the proposed method is reliable if compared to the thermodilution. Considering the non-invasivity of the technique, further evaluations of its performances are encouraged.
-
J Clin Monit Comput · Dec 2014
Clinical TrialDetection of respiratory compromise by acoustic monitoring, capnography, and brain function monitoring during monitored anesthesia care.
Episodes of apnea in sedated patients represent a risk of respiratory compromise. We hypothesized that acoustic monitoring would be equivalent to capnography for detection of respiratory pauses, with fewer false alarms. In addition, we hypothesized that the patient state index (PSI) would be correlated with the frequency of respiratory pauses and therefore could provide information about the risk of apnea during sedation. ⋯ For the 51 respiratory pauses validated by retrospective analysis, the sensitivity, specificity, and likelihood ratio positive for detection were 16, 96 %, and 3.5 for clinician observation; 88, 7 %, and 1.0 for capnography; and 55, 87 %, and 4.1 for acoustic monitoring. There was no correlation between PSI and respiratory pause events. Acoustic monitoring had the highest likelihood ratio positive for detection of respiratory pause events compared with capnography and clinician observation and, therefore, may provide the best method for respiration rate monitoring during these procedures.
-
J Clin Monit Comput · Dec 2014
Measuring gas exchange with step changes in inspired oxygen: an analysis of the assumption of oxygen steady state in patients suffering from COPD.
Bedside estimation of pulmonary gas exchange efficiency may be possible from step changes in FIO2 and subsequent measurement of arterial oxygenation at steady state conditions. However, a steady state may not be achieved quickly after a change in FIO2, especially in patients with lung disease such as COPD, rendering this approach cumbersome. This paper investigates whether breath by breath measurement of respiratory gas and arterial oxygen levels as FIO2 is changed can be used as a much more rapid alternative to collecting data from steady state conditions for measuring pulmonary gas exchange efficiency. ⋯ Calculated model parameters were shown to be similar for the two data sets, with Bland-Altman bias and limits of agreement of -0.4 and -3.0 to 2.2 % for calculation of pulmonary shunt and 0.17 and -0.47 to 0.81 kPa for alveolar to end-capillary PO2, a measure of oxygen abnormality due to shunting plus regions of low [Formula: see text] A/[Formula: see text] ratio. This study shows that steady state oxygen levels may not be necessary when estimating pulmonary gas exchange using changes in FIO2. As such this technique may be applicable in patients with lung disease such as COPD.
-
J Clin Monit Comput · Dec 2014
Melodic algorithms for pulse oximetry to allow audible discrimination of abnormal systolic blood pressures.
An anesthesiologist must remain vigilant of the patient's clinical status, incorporating many independent physiological measurements. Oxygen saturation and heart rate are represented by continuous audible tones generated by the pulse oximeter, a mandated monitoring device. Other important clinical parameters--notably blood pressure--lack any audible representation beyond arbitrarily-configured threshold alarms. ⋯ A rhythmic variation in which additional auditory information was conveyed only at halftime intervals, with every other "beat" of the pulse oximeter, was strongly favored. The respondents also strongly favored the use of musical chords over single tones. Given three algorithms of tones embedded in the pulse oximeter signal, anesthesiologists preferred a melodic tone to signal a significant change in blood pressure.