Journal of clinical monitoring and computing
-
J Clin Monit Comput · Jun 2014
Validity and reliability of the Cold Discomfort Scale: a subjective judgement scale for the assessment of patient thermal state in a cold environment.
Complementary measures for the assessment of patient thermoregulatory state, such as subjective judgement scales, might be of considerable importance in field rescue scenarios where objective measures such as body core temperature, skin temperature, and oxygen consumption are difficult to obtain. The objective of this study was to evaluate, in healthy subjects, the reliability of the Cold Discomfort Scale (CDS), a subjective judgement scale for the assessment of patient thermal state in cold environments, defined as test-retest stability, and criterion validity, defined as the ability to detect a difference in cumulative cold stress over time. Twenty-two healthy subjects performed two consecutive trials (test-retest). ⋯ The comparison revealed that CDS ratings were significantly increased for every interval of 10, 15, and 30 min (p < 0.001) but not for every interval of 5 min. In conclusion, in a prehospital scenario, subjective judgement scales might be a valuable measure for the assessment of patient thermal state. The results of this study indicated that, in concious patients, the CDS may be both reliable and valid for such purpose.
-
J Clin Monit Comput · Jun 2014
Case ReportsBeware of "curare cleft" like changes during unilateral capnothorax.
Capnography is a standard monitoring tool during general anaesthesia. Diaphragmatic movement with the weaning of muscle relaxant effect produces the characteristic "curare cleft" on capnography. ⋯ Cautious interpretation and identification of these is essential to avoid any undue overdosing of the patients with muscle relaxants. We report "curare cleft" like artefact during ventilation with a single lumen tube in a patient with unilateral capnothorax undergoing minimally invasive esophagectomy.
-
J Clin Monit Comput · Jun 2014
Randomized Controlled Trial Comparative StudyE-O technique is superior to E-C technique in manikins during single person bag mask ventilation performed by novices.
Conventional E-C technique of mask holding is unreliable during single person bag mask ventilation (BMV) due mainly to leak around the mask and inexperience of the persons. In this manikin study, conventional E-C technique was compared with E-O technique during single person BMV both with experienced (n = 50) and novice (n = 50) volunteers. The E-O technique involved encircling the mask neck with the web between thumb and index finger while the other digits provided chin lift. ⋯ The conventionally taught E-C technique of single person BMV provides acceptable chest expansion on most occasions with experienced operators than novices. Novices should use E-O technique as the first choice for single person BMV. Both techniques may be used interchangeably when one fails.
-
J Clin Monit Comput · Jun 2014
Randomized Controlled TrialInexpensive video-laryngoscopy guided intubation using a personal computer: initial experience of a novel technique.
Video-laryngoscopy may provide an enhanced view of laryngeal structures compared to direct visualization. Commercial video-laryngoscopes are often expensive, limiting its adoption for routine use. We describe our initial experience using an inexpensive custom made device. ⋯ The custom-made, inexpensive, video-laryngoscopy device is safe and reliable for clinical use. Real-time visualization and endotracheal intubation were successful in all patients, including those with anticipated difficult airway. Further, this device helps in archiving the video of intubation.
-
J Clin Monit Comput · Jun 2014
Application of internal electrodes to the oesophageal and tracheal tube in an animal trial: evaluation of its clinical and technical potentiality in electrical impedance tomography.
Electrical impedance tomography (EIT) is of potential medical interest e.g., to optimize ventilator settings during mechanical ventilation. Nevertheless there are still several challenges. Although electrode belts are commonly used and promoted, they are not necessarily adequate for the long-term monitoring of patients in intensive-care units (ICU). ⋯ Distinguishability of lungs was improved in reconstructed frames. The resulting sensitivity of measured electrical impedance was enhanced around the mediastinal region and even cardiac-related activity was significantly increased by a factor of up to 6. In conclusion the application of internal electrodes appears to be beneficial for diverse clinical purposes and should be addressed in further studies.