Journal of clinical monitoring and computing
-
J Clin Monit Comput · Oct 2017
Frequency-domain vs continuous-wave near-infrared spectroscopy devices: a comparison of clinically viable monitors in controlled hypoxia.
The Near-infrared spectroscopy (NIRS) has not been adopted as a mainstream monitoring modality in acute neurosurgical care due to concerns about its reliability and consistency. However, improvements in NIRS parameter recovery techniques are now available that may improve the quantitative accuracy of NIRS for this clinical context. Therefore, the aim of this study was to compare the abilities of a continuous-wave (CW) NIRS device with a similarly clinically viable NIRS device utilising a frequency-domain (FD) parameter recovery technique in detecting changes in cerebral tissue saturation during stepwise increases of experimentally induced hypoxia. ⋯ No significant difference was observed between the saturation changes observed by either device (P = 0.625). An observably greater degree of noise was noticed in parameters recovered by the FD device, and both demonstrated equally variable baseline readings (Coefficient of variance 8.4 and 9.7 % for the CW and FD devices, respectively) between individuals tested. No advantageous difference was observed in parameters recovered from the FD device compared with those detected by CW.
-
J Clin Monit Comput · Oct 2017
Efficacy and safety of novel high-frequency multi-train stimulation for recording transcranial motor evoked potentials in a rat model.
Recently, low-frequency multi-train stimulation (MTS) was shown to effectively enhance transcranial motor-evoked potentials (TcMEPs). In contrast, high- frequency double-train stimulation was reported to elicit a marked facilitation. The aim of this study was to evaluate the efficacy of high-frequency MTS in the augmentation of potentials. ⋯ The aversion index was >0.8 in all animals after they received 100 high-frequency MTSs. Histologically, no pathological changes were evident in the rat brains. High-frequency MTS shows potential to effectively enhance TcMEP responses, and to be used safely in transcranial brain stimulation.
-
J Clin Monit Comput · Oct 2017
Multicenter StudyNon-invasive diagnosis of pulmonary hypertension from lung Doppler signal: a proof of concept study.
Transthoracic Parametric Doppler (TPD) is a novel ultrasound technique recently developed for the investigation of pulmonary blood vessels. Lung Doppler Signals (LDS) recorded from TPD provide information regarding the functional mechanical characteristics of pulmonary blood vessels. We aimed to define the specific profile of LDS generated from TPD imaging in patients with pulmonary hypertension (PH), and to evaluate the diagnostic performance of LDS to detect PH using right heart catheterization (RHC) as gold standard reference. ⋯ Detection rate of PH increased progressively with the level of mean pulmonary artery pressure. LDS recorded by TPD display a specific profile in PH and appears to be a promising and reliable tool for PH diagnosis. Further studies are required to confirm the clinical usefulness of LDS.
-
J Clin Monit Comput · Oct 2017
Introduction of a new electronic medical record system has mixed effects on first surgical case efficiency metrics.
To evaluate the effect of deploying a new electronic medical record (EMR) system on first case starts in the operating room. Data on first case start times were collected after implementation of a new EMR (Epic) from June 2015 to May 2016, which replaced a legacy system of both paper and electronic records. These were compared to data from the same months in the three proceeding years. ⋯ First month FPIR delays were not limited to any one specialty. EMRs have the potential to improve hospital workflows, but are not without learning curves. FPIR and FCOTS delays return to baseline after a few months, and in the case of FCOTS, can improve beyond baseline.
-
J Clin Monit Comput · Oct 2017
Comparative StudyObservation of ventilation effects of I-gel™, Supreme™ and Ambu AuraOnce™ with respiratory dynamics monitoring in small children.
The shortcomings of laryngeal mask airway (LMA™), such as upper airway obstruction and gastric distension or airway leakage, may limit its application in small children. The I-gel™ (I-gel), LMA-Supreme™ (LMA-S), and Ambu AuraOnce™ (Ambu) are three improvements upon these shortcomings. This study adopted respiratory dynamic monitoring to observe the ventilation parameters of the three laryngeal masks in small children. ⋯ At T3 and T4, the expiratory resistance values in the Ambu group were significantly lower than those in the LMA-S group (P < 0.05). We have shown that the three laryngeal masks provided secure ventilation in children <6 years of age by using continuous respiratory dynamic monitoring. We concluded that the I-gel presented a better sealing effect and fewer adverse reactions.