ReviewA sneak peek into digital innovations and wearable sensors for cardiac monitoring.
Many mobile phone or tablet applications have been designed to control cardiovascular risk factors (obesity, smoking, sedentary lifestyle, diabetes and hypertension) or to optimize treatment adherence. Some have been shown to be useful but the long-term benefits remain to be demonstrated. Digital stethoscopes make easier the interpretation of abnormal heart sounds, and the development of pocket-sized echo machines may quickly and significantly expand the use of ultrasounds. ⋯ They have the potential to change the way we monitor and treat patients with cardiovascular diseases in the hospital and beyond. Some may have the ability to improve quality of care, decrease the number of medical visits and hospitalization, and ultimately health care costs. Validation and outcome studies are needed to clarify, among the growing number of digital innovations and wearable sensors, which tools have real clinical value.
-
J Clin Monit Comput · Apr 2017
To characterize the incidence of airway misplacement of nasogastric tubes in anesthetized intubated patients by using a manometer technique.
This study characterized the incidence of airway misplacement of nasogastric (NG) tubes in surgical patients, and the benefit of using a manometer to discriminate gastric placement from airway placement of NG tubes. Subjects included adult patients scheduled for abdominal surgery. After tracheal intubation, a 16 Fr. ⋯ For confirmation of gastric placement, the auscultation technique had a sensitivity of 100.0 % and a specificity of 79.3 %. In contrast, the manometer technique had a sensitivity of 100.0 % and a specificity of 100.0 % in the discrimination of gastric placement from airway placement of NG tubes. Airway misplacement of NG tubes is not uncommon in surgical patients, and the manometer technique may be a reliable and safe method to discriminate gastric placement from airway placement of NG tubes.
-
J Clin Monit Comput · Apr 2017
Observational StudyUtility of stroke volume variation measured using non-invasive bioreactance as a predictor of fluid responsiveness in the prone position.
The aim of this prospective study was to evaluate the usefulness of stroke volume variation (SVV) derived from NICOM® to predict fluid responsiveness in the prone position. Forty adult patients undergoing spinal surgery in the prone position were included in this study. We measured SVV from NICOM® (SVVNICOM) and FloTrac™/Vigileo™ systems (SVVVigileo), and pulse pressure variation (PPV) using automatic (PPVauto) and manual (PPVmanual) calculations at four time points including supine and prone positions, and before and after fluid loading of 6 ml kg-1 colloid solution. ⋯ The optimal cut-off values were 12 % for SVVNICOM, SVVVigileo, and PPVauto, and 10 % for PPVmanual. SVV from NICOM® successfully predicts fluid responsiveness during surgery in the prone position. This totally non-invasive technique for assessing individual functional intravenous volume status would be useful in a wide range of surgeries performed in the prone position.
-
J Clin Monit Comput · Apr 2017
Randomized Controlled TrialA novel system for automated propofol sedation: hybrid sedation system (HSS).
Closed-loop systems for propofol have been demonstrated to be safe and reliable for general anesthesia. However, no study has been conducted using a closed-loop system specifically designed for sedation in patients under spinal anesthesia. We developed an automatic anesthesia sedation system that allows for closed-loop delivery of propofol for sedation integrating a decision support system, called the hybrid sedation system (HSS). ⋯ Data are presented as mean ± standard deviation, groups were compared using t test or Chi square test, P < 0.05. Clinical performance of sedation showed 'Excellent' control in the HSS-group for a significantly longer period of time (49 vs. 26 % in the control group, P < 0.0001). 'Poor' and 'Inadequate' sedation was significantly shorter in the HSS Group compared to the Control Group (11 and 10 % vs. 20 and 18 %, respectively, P < 0.0001). The novel, closed-loop system for propofol sedation showed better maintenance of the target BIS value compared to manual administration.
-
J Clin Monit Comput · Apr 2017
Comparative StudyA head to head evaluation of 8 biochemical scanning tools for unmeasured ions.
We aimed to evaluate the sensitivity and specificity of 8 biochemical scanning tools in signalling the presence of unmeasured anions. We used blood gas and biochemical data from 15 patients during and after cardio-pulmonary bypass. Sampling time-points were pre-bypass (T1), 2 min post equilibration with priming fluid containing acetate and gluconate anions (T2), late bypass (T3) and 4 h after surgery (T4). ⋯ At an [XA] threshold of 6 mEq/L, areas under receiver -operator characteristic curves in rank order were IPEua and UIX (0.88 and 0.87 respectively), SIG (0.81), AGc (0.79), standard BE gap (0.77), plasma BE gap (0.71), BE gap (0.70) and AG (0.59). Similar ranking hierarchies applied to positive and negative predictive values. We conclude that during acute hemodilution UIX and IPEua are superior to the anion gap (with and without albumin correction) and 4 other indices as scanning tools for unmeasured anions.