Journal of clinical monitoring and computing
-
J Clin Monit Comput · Jun 2017
Analysis of central venous pressure (CVP) signals using mathematical methods.
Central venous pressure (CVP) is an important clinical parameter for physicians but only the absolute CVP value is typically monitored in the intensive care unit (ICU). In this study, we propose a novel mathematical method to present and analyze CVP signals. ⋯ The statistical features of time and frequency domain, wavelet, and empirical mode decomposition of these signals were extracted. We found no significant difference among the CVP signals regarding sex, smoking, coronary disease, and respiration mode of the samples.
-
J Clin Monit Comput · Jun 2017
ReviewUrine biochemistry assessment in critically ill patients: controversies and future perspectives.
In the past, urine biochemistry was a major tool in acute kidney injury (AKI) management. Classic papers published some decades ago established the values of the urine indices which were thought to distinguish "pre-renal" (functional) AKI attributed to low renal perfusion and "renal" (structural) AKI attributed to acute tubular necrosis (ATN). However, there were a lot of drawbacks and limitations in these studies and some recent articles have questioned the utility of measuring urine electrolytes especially because they do not seem to adequately inform about renal perfusion nor AKI duration (transient vs. persistent). ⋯ Some studies have suggested standardized changes in the urine electrolyte composition preceding increases in serum creatinine independently of AKI subsequent duration, which might actually be due to intra-renal microcirculatory changes and activation of sodium-retaining mechanisms even in the absence of impaired global renal blood flow. In the present review, the points of controversy regarding urine biochemistry assessment were evaluated as well as future perspectives for its role in AKI monitoring. An alternative approach for the interpretation of measured urine electrolytes is proposed which needs further larger studies to be validated and incorporated in daily ICU practice.
-
J Clin Monit Comput · Jun 2017
Assessment of continuous acoustic respiratory rate monitoring as an addition to a pulse oximetry-based patient surveillance system.
Technology advances make it possible to consider continuous acoustic respiratory rate monitoring as an integral component of physiologic surveillance systems. This study explores technical and logistical aspects of augmenting pulse oximetry-based patient surveillance systems with continuous respiratory rate monitoring and offers some insight into the impact on patient deterioration detection that may result. Acoustic respiratory rate sensors were introduced to a general care pulse oximetry-based surveillance system with respiratory rate alarms deactivated. ⋯ Continuous respiratory rate monitoring can be successfully added to a pulse oximetry-based surveillance system without significant technical, logistical or workflow issues and is moderately well-tolerated by patients. Respiratory rate sensor alarms did not significantly impact overall system alarm burden. Respiratory rate and oxygen saturation distributions suggest adding continuous respiratory rate monitoring to a pulse oximetry-based surveillance system may not significantly improve patient deterioration detection.
-
J Clin Monit Comput · Jun 2017
Observational StudyConsistency of cardiac function index and global ejection fraction with global end-diastolic volume in patients with femoral central venous access for transpulmonary thermodilution: a prospective observational study.
Global ejection fraction (GEF) and cardiac function index (CFI) are transpulmonary thermodilution (TPTD)-derived indices of the systolic function. Their validity relies on an accurate determination of the global end-diastolic volume (GEDV). Due to an overestimation of GEDV using a femoral central venous catheter (CVC) a correction formula for indexed GEDV (GEDVI) has been implemented in the latest PiCCO™-algorithm. ⋯ By contrast, GEFcalculated (23.1 ± 8.7 %) was not substantially different from GEFdisplayed (22.4 ± 8.6 %). Although GEDV and GEF are corrected for femoral CVC site, this does not apply to CFI. However, all indices derived from GEDV should be calculated consistently.
-
J Clin Monit Comput · Jun 2017
Randomized Controlled TrialPreheating of streamlined liner of pharyngeal airway (SLIPA) reduced the related complications: a randomized control study.
This study was designed to verify whether preheating could decrease the complications that may be associated with the use of streamlined liner of pharyngeal airway (SLIPA). We evaluated the incidence of sore throat, maximum sealing pressure, hoarseness and blood stains after preheating of SLIPA. Eighty patients scheduled for hysteroscopic surgery to whom the SLIPA was considered suitable were randomly allocated to preheating group or control group. ⋯ However there was no statistical difference in the maximum sealing pressure. Our results suggest preheating of the SLIPA decreased the complications related with the insertion of SLIPA. Clinical Trials.gov Identifier NCT02539485.