Journal of clinical monitoring and computing
-
J Clin Monit Comput · Oct 2018
Observational StudyLow minute ventilation episodes during anesthesia recovery following intraperitoneal surgery as detected by a non-invasive respiratory volume monitor.
An electrical impedance-based noninvasive respiratory volume monitor (RVM) accurately reports minute volume, tidal volume and respiratory rate. Here we used the RVM to quantify the occurrence of and evaluate the ability of clinical factors to predict respiratory depression in the post-anesthesia care unit (PACU). RVM generated respiratory data were collected from spontaneously breathing patients following intraperitoneal surgeries under general anesthesia admitted to the PACU. ⋯ Low respiratory rate was a poor predictor of LMVe (sensitivity = 11.8%). Other clinical variables (e.g., obstructive sleep apnea) were not found to be predictors of LMVe. Using RVM we identified that mild, clinically nondetectable, respiratory depression prior to opioid administration in the PACU was associated with the development of substantial subsequent respiratory depression during the PACU stay.
-
J Clin Monit Comput · Oct 2018
ReviewAssessment of liver perfusion and function by indocyanine green in the perioperative setting and in critically ill patients.
Indocyanine green (ICG) is a water-soluble dye that is bound to plasma proteins when administered intravenously and nearly completely eliminated from the blood by the liver. ICG elimination depends on hepatic blood flow, hepatocellular function and biliary excretion. ICG elimination is considered as a useful dynamic test describing liver function and perfusion in the perioperative setting, i.e., in liver surgery and transplantation, as well as in critically ill patients. ICG plasma disappearance rate (ICG-PDR) which can be measured today by transcutaneous systems at the bedside is a valuable method for dynamic assessment of liver function and perfusion, and is regarded as a valuable prognostic tool in predicting survival of critically ill patients, presenting with sepsis, ARDS or acute liver failure.
-
J Clin Monit Comput · Oct 2018
Observational StudyPredictive values of pulse pressure variation and stroke volume variation for fluid responsiveness in patients with pneumoperitoneum.
Animal studies suggest that dynamic predictors remain useful in patients with pneumoperitoneum, but human data is conflicting. Our aim was to determine predictive values of pulse pressure variation (PPV) and stroke volume variation (SVV) in patients with pneumoperitoneum using LiDCORapid™ haemodynamic monitor. Standardised fluid challenges of colloid were administered to patients undergoing laparoscopic procedures, one fluid challenge per patient. ⋯ The gray zone of PPV ranged between 6.5 and 20.5% and that of SVV between 7.5 and 13%. During pneumoperitoneum, as measured by LiDCORapid™, PPV and SVV can predict fluid responsiveness, however their sensitivity is lower than the one reported in conditions without pneumoperitoneum. Trial registry number: (with the Australian New Zealand Clinical Trials Registry): ACTRN12612000456853.
-
J Clin Monit Comput · Oct 2018
Video-based heart rate monitoring across a range of skin pigmentations during an acute hypoxic challenge.
The robust monitoring of heart rate from the video-photoplethysmogram (video-PPG) during challenging conditions requires new analysis techniques. The work reported here extends current research in this area by applying a motion tolerant algorithm to extract high quality video-PPGs from a cohort of subjects undergoing marked heart rate changes during a hypoxic challenge, and exhibiting a full range of skin pigmentation types. High uptimes in reported video-based heart rate (HRvid) were targeted, while retaining high accuracy in the results. ⋯ The difference between the HRvid and HRp exceeded 5 and 10 bpm, for 3.59 and 0.35% of the reporting time respectively, and at no point did these differences exceed 25 bpm. Excellent agreement was found between the HRvid and HRp in a study covering the whole range of skin pigmentation types (Fitzpatrick scales I-VI), using standard room lighting and with moderate subject motion. Although promising, further work should include a larger cohort with multiple subjects per Fitzpatrick class combined with a more rigorous motion and lighting protocol.
-
J Clin Monit Comput · Oct 2018
Comparative StudyComparison of blood pressure monitoring by applanation tonometry and invasively assessed blood pressure in cardiological patients.
The aim of this study was to evaluate the accuracy and precision of non-invasive continuous blood pressure measurement by applanation tonometry (AT) in awake or anaesthetised cardiological intensive care patients. Patients suffering from highly impaired left ventricular function atrial fibrillation or severe aortic valve stenosis were included into the study. Arterial blood pressure was recorded by applanation tonometry (T-Line 400, Tensys Medical®, USA) and an arterial line in awake or anaesthetised patients. ⋯ For all patients bias for MAPAT compared to MAPAL was 14.96 mmHg (SAPAT 4.51 mmHg; DAPAT 19.12 mmHg) with limits of agreement for MAPAT of 46.25 and - 16.33 mm Hg (SAPAT 48.00 and - 38.98 mmHg; DAPAT 50.12 and - 11.89 mmHg). Percentage error for MAPAT was 56.8% (42.7% for SAPAT; 75.2% for DAPAT). We conclude that the AT method is not reliable in ICU patients with severe cardiac comorbidities.