Journal of clinical monitoring and computing
-
J Clin Monit Comput · Oct 2018
Somatosensory evoked potentials after decompressive craniectomy for traumatic brain injury.
Somatosensory evoked potentials (SSEPs) are used for neuroprognosis after severe traumatic brain injury (TBI). However decompressive craniectomy (DC), involving removal of a portion of the skull to alleviate elevated intracranial pressure, is associated with an increase in SSEP amplitude. Accordingly, SSEPs are not available for neuroprognosis over the hemisphere with DC. ⋯ For contralateral-ipsilateral montages r2 was 0.28 and for frontal pole montages r2 was 0.62. Cortical SSEP amplitudes are influenced by the presence of cortical bone as is particularly evident in frontal pole montages. Larger, longitudinal trials to assess feasibility of neuroprognosis over the hemisphere with DC in severe TBI patients are warranted.
-
Using the thyromental distance (TMD) measured based on the ultrasonographic location of the thyroid cartilage prominence as the criterion, we investigated the accuracy of TMD measurement by surface landmark identification of the thyroid cartilage prominence. Twenty-nine anesthetist resident volunteers were recruited, including 10 first-year residents, 9 second-year residents and 10 third-year residents. Each volunteer measured the other 28 volunteers' TMD. ⋯ The error rates of anesthetist residents of first-year, second-year and third-year were 34, 27, and 31%, respectively, and were not significantly different. The error of TMD measurement by surface landmark identification is often, especially for women. More clinic experience don't improve it.
-
J Clin Monit Comput · Oct 2018
Observational StudyPredictive values of pulse pressure variation and stroke volume variation for fluid responsiveness in patients with pneumoperitoneum.
Animal studies suggest that dynamic predictors remain useful in patients with pneumoperitoneum, but human data is conflicting. Our aim was to determine predictive values of pulse pressure variation (PPV) and stroke volume variation (SVV) in patients with pneumoperitoneum using LiDCORapid™ haemodynamic monitor. Standardised fluid challenges of colloid were administered to patients undergoing laparoscopic procedures, one fluid challenge per patient. ⋯ The gray zone of PPV ranged between 6.5 and 20.5% and that of SVV between 7.5 and 13%. During pneumoperitoneum, as measured by LiDCORapid™, PPV and SVV can predict fluid responsiveness, however their sensitivity is lower than the one reported in conditions without pneumoperitoneum. Trial registry number: (with the Australian New Zealand Clinical Trials Registry): ACTRN12612000456853.
-
J Clin Monit Comput · Oct 2018
Evaluation of the use of the fourth version FloTrac system in cardiac output measurement before and after cardiopulmonary bypass.
The FloTrac system is a system for cardiac output (CO) measurement that is less invasive than the pulmonary artery catheter (PAC). The purposes of this study were to (1) compare the level of agreement and trending abilities of CO values measured using the fourth version of the FloTrac system (CCO-FloTrac) and PAC-originated continuous thermodilution (CCO-PAC) and (2) analyze the inadequate CO-discriminating ability of the FloTrac system before and after cardiopulmonary bypass (CPB). Fifty patients were included. ⋯ The area under the receiver operating characteristic curve for CCO-FloTrac was 0.56, 0.52, 0.52, and 0.72 for all, ≥ ± 5, ≥ ± 10, and ≥ ± 15% CO changes (ΔCO) of CCO-PAC before CPB, respectively, and 0.59, 0.55, 0.49, and 0.46 for all, ≥ ± 5, ≥ ± 10, and ≥ ± 15% ΔCO of CCO-PAC after CPB, respectively. When CO < 4 L/min was considered inadequate, the Cohen κ coefficient was 0.355 and 0.373 before and after CPB, respectively. The accuracy, trending ability, and inadequate CO-discriminating ability of the fourth version of the FloTrac system in CO monitoring are not statistically acceptable in cardiac surgery.