Journal of clinical monitoring and computing
-
J Clin Monit Comput · Dec 2018
Respiratory changes in subclavian vein diameters predicts fluid responsiveness in intensive care patients: a pilot study.
The present pilot study investigated whether respiratory variation in subclavian vein (SCV) diameters correlates with fluid responsiveness in mechanically ventilated patients. Monocentric, prospective clinical study on fluid responsiveness in adult sedated, mechanically ventilated ICU patient, monitored with the PiCCO™ system (Pulsion Medical System, Germany), and requiring a fluid challenge (FC). A 10-min fluid bolus of 500 mL of 0.9% saline was administered. ⋯ Other parameters, such as SVV and PPV, could not predict fluid responsiveness. The correlation coefficient between CO variation and the SCVvariability index was 0.73 (p < 0.001). The SCVvariability index was a reliable, non-invasive parameter for the prediction of fluid responsiveness at the bedside of mechanically ventilated, critically ill patients in this pilot study.
-
J Clin Monit Comput · Dec 2018
Observational StudyAssessment of changes in blood glucose concentration with intravascular microdialysis.
Blood glucose and its variability of is a major prognostic factor associated with morbidity. We hypothesized that intravenous microdialysis incorporated in a central venous catheter (CVC) would be interchangeable with changes in blood glucose measured by the reference method using a blood gas analyzer. Microdialysis and central venous blood glucose measurements were simultaneously recorded in high-risk cardiac surgical patients. ⋯ Among the remaining 63 (82%) interpretable changes, 23 (37%) were interchangeable, 13 (20%) were in the gray zone, and 27 (43%) were not interchangeable. Microdialysis using a CVC appears to provide imprecise absolute blood glucose values with risk of insulin misuse. Moreover, only one third of changes in blood glucose measurements were interchangeable with the reference method using the TIM.
-
J Clin Monit Comput · Dec 2018
Letter Case ReportsMagnetic resonance imaging (MRI) induced 'hypoxia artifacts' on pulse oximetry: how reliable are MRI compatible monitoring devices?
Distinguishing a monitoring artifact requires expertise and adeptness. This can be practically challenging during the course of an anesthetic. We report a case, wherein we experienced episodes of aberrant pulse-oximeter values suggestive of desaturation with normal waveforms, occurring during a particular sequence of magnetic resonance imaging (MRI) performed under general anesthesia, which in fact was an artifact induced by the 3 T MRI during the diffusion tensor imaging sequence.
-
J Clin Monit Comput · Dec 2018
Computer simulated modeling of healthy and diseased right ventricular and pulmonary circulation.
We have previously developed a simulated cardiovascular physiology model for in-silico testing and validation of novel closed-loop controllers. To date, a detailed model of the right heart and pulmonary circulation was not needed, as previous controllers were not intended for use in patients with cardiac or pulmonary pathology. With new development of controllers for vasopressors, and looking forward, for combined vasopressor-fluid controllers, modeling of right-sided and pulmonary pathology is now relevant to further in-silico validation, so we aimed to expand our existing simulation platform to include these elements. ⋯ In the pulmonary hypertension model, pulmonary blood volume of 615 ± 90 ml, pulmonary arterial pressures of 80 ± 14 mmHg systolic, 36 ± 7 mmHg diastolic, and the left atrial pressure of 11 ± 2 mmHg all met criteria for acceptance. For CI, the simulated value of 2.8 ± 0.4 l/min/m2 once again had a narrower spread than most of the published data, but fell inside of the SD of all published data, and the PVR value of 7.5 ± 1.6 wood units fell in the middle of the four published studies. The right-ventricular and pulmonary circulation simulation appears to be a reasonable approximation of the right-sided circulation for healthy physiology as well as the pathologic conditions tested.
-
J Clin Monit Comput · Dec 2018
Editorial CommentBoosting systemic pressure with phenylephrine: arterial or venous modulation?
Abstract