Efficiency of oxygen delivery through different oxygen entrainment devices during sedation under low oxygen flow rate: a bench study.
Sedative anesthetic procedures outside the operating room may depend on cylinders as oxygen source. Cylinders have limited storage capacity and a low oxygen flow rate improves the durability. We conducted the bench study to evaluate the fraction of inspired oxygen (FiO2) in different oxygen entrainment devices under low oxygen flow rate. ⋯ In the hypoventilation group, oxygen reservoir units helped oxygen retention in local area and maintained a higher oxygen concentration. There were multiple factors lead to different oxygen fraction that we measured, such as different devices, respiratory patterns, and oxygen reservoir units. The result of our bench study provided some information for anesthesiologist to choose appropriate oxygen entrainment devices in various sedative anesthetic procedures.
-
J Clin Monit Comput · Jun 2018
Comparative StudyDiscrepancy between in vivo and in vitro comparisons of forced oscillation devices.
The forced oscillation technique (FOT) is an emerging clinical lung function test, with commercial devices becoming increasingly available. However comparability across existing devices has not been established. We evaluated in vivo and in vitro measurements made using three commercial devices against a custom-built device (WIMR): Resmon Pro Diary (Restech srl, Italy), tremoFlo C-100 (Thorasys Medical Systems, Canada), Jaeger Masterscope CT IOS (CareFusion, Hoechberg, Germany). ⋯ No differences were observed using test standards; deviation from theoretical value was <2% for resistance and <5% for reactance. The WIMR, tremoFlo and Resmon Pro but not IOS devices measure similar Rrs, whereas there was more disparity across devices in the estimation of Xrs parameters. The discrepancy between in vivo and in vitro measurements suggest that FOT validation procedures need to take into account the breathing pattern, either using biological controls or a breathing model.
-
J Clin Monit Comput · Jun 2018
Comparative StudyComparing volume-clamp method and intra-arterial blood pressure measurements in patients with atrial fibrillation admitted to the intensive or medium care unit.
International guidelines highlight the importance of blood pressure (BP) in patients with atrial fibrillation (AF). However, BP measurement in AF is complicated by beat-to-beat fluctuation. Automated BP measurement devices are not validated for patients with AF and no consensus exists on how to measure BP in AF manually. ⋯ Accuracy of VCM in AF was similar to sinus rhythm. In conclusion, in patients with AF, accurate and precise measurement of non-invasive beat-to-beat BP measurement using the VCM is possible, the one exception being the precision of systolic BP. Beat-to-beat variability can be accurately reproduced.
-
J Clin Monit Comput · Jun 2018
Randomized Controlled TrialThe effect of intravenous lidocaine infusion on bispectral index during major abdominal surgery.
Intraoperative lidocaine infusion has become widely accepted as an adjunct to general anesthesia where its use has been associated with opioid-sparing and enhanced recovery. The aims of this study were to determine whether or not intravenous (IV) lidocaine infusion (a) has an anesthetic sparing effect during major colorectal procedures and (b) if it also affects level of hypnosis as measured by bispectral index (BIS). Twenty-five patients undergoing laparotomy for resection of colorectal tumours were randomized to receive either IV lidocaine (1.5 mg kg-1 bolus then 1 mg kg-1 per hour) or an equivalent volume of normal saline commenced after intravenous induction of general anesthesia. ⋯ Higher BIS values in the lidocaine versus placebo group may indicate that levels of hypnosis were not equivalent. Alternatively, BIS may not be a sensitive indicator of synergistic interactions between local anesthetic and volatile agent. Our results advocate a cautious approach to titration of general anesthesia when combined with lidocaine infusion.
-
J Clin Monit Comput · Jun 2018
ReviewA review of recent advances in data analytics for post-operative patient deterioration detection.
Most deaths occurring due to a surgical intervention happen postoperatively rather than during surgery. The current standard of care in many hospitals cannot fully cope with detecting and addressing post-surgical deterioration in time. For millions of patients, this deterioration is left unnoticed, leading to increased mortality and morbidity. ⋯ This work also aims to highlight the opportunities that lie in personalizing the models developed for patient deterioration for these particular post-surgical patients and make the output more actionable. The integration of pre- and intra-operative data, e.g. comorbidities, vitals, lab data, and information about the procedure performed, in post-operative early warning algorithms would lead to more contextualized, personalized, and adaptive patient modelling. This, combined with careful integration in the clinical workflow, would result in improved clinical decision support and better post-surgical care outcomes.