Journal of clinical monitoring and computing
-
J Clin Monit Comput · Dec 2022
Prospective validation of gas man simulations of sevoflurane in O2/air over a wide fresh gas flow range.
The use of inhaled anesthetics has come under increased scrutiny because of their environmental effects. This has led to a shift where sevoflurane in O2/air has become the predominant gas mixture to maintain anesthesia. To further reduce environmental impact, lower fresh gas flows (FGF) should be used. ⋯ During the first 15 min, MDPE and MDAPE were 7% [- 6, 28] and 13% [6, 32], respectively, and during the last 45 min - 1% [- 5, 5] and 5% [2, 9], respectively. In conclusion, Gas Man® predicts FETsevo in O2/air in adults over a wide range of FGF and vaporizer settings using different workstations with both MDPE and MDAPE < 10% during the first hour of anesthesia, with better relative performance for simulating maintenance than wash-in. In the authors' opinion, this degree of performance suffices for Gas Man® to be used to quantify the environmental impact of FGF reduction in real life practice of the wash-in and maintenance period combined.
-
To describe an alternative method of measuring the Epidural Waveform Analysis (EWA), a technique through which anesthesiologists can confirm the position of a needle and/or catheter tip in the epidural space. EWA consists of epidural catheter transduction with a pressure system typically used for invasive arterial blood pressure monitoring which generates a characteristic oscillatory waveform (provided the catheter tip is within the epidural space) in synchrony with the pulsatile epidural circulation. ⋯ EWA allows anesthesiologists to confirm the correct position of an epidural needle/catheter. We describe a method of successfully measuring EWA while reducing wastefulness.
-
J Clin Monit Comput · Dec 2022
Review Case ReportsIntraoperative recording of laryngeal adductor reflex and cortical motor evoked potentials during jugular foramen schwannoma surgery: a case report and literature review.
Schwannoma, a tumor originating from the peripheral nervous system, may arise from the vagus nerve, although it is not very often. Injury of the vagus nerve by surgical attempts may have consequences that will seriously affect the patient's quality of life. In recent years, continuous monitoring of the laryngeal adductor reflex (LAR) has become a promising methodology for evaluating vagus nerve function intraoperatively. We refer to our experience changing our surgical strategy due to concurrent deterioration in LAR and CoMEPs intraoperatively. We also provide a literature review and summarize the current knowledge of this technique. ⋯ We conclude that LAR with vagal nerve CoMEPs are two complementary methods and provide reliable information about the functional status of the vagus nerve during surgery.
-
J Clin Monit Comput · Dec 2022
Randomized Controlled TrialEffect of intraoperative personalized goal-directed hemodynamic management on acute myocardial injury in high-risk patients having major abdominal surgery: a post-hoc secondary analysis of a randomized clinical trial.
Acute myocardial injury is common after noncardiac surgery and associated with mortality. Impaired intraoperative cardiovascular dynamics are a risk factor for acute myocardial injury. Optimizing intraoperative cardiovascular dynamics may thus reduce acute myocardial injury. ⋯ Acute myocardial injury occurred in 4 of 90 patients (4%) in the personalized goal-directed hemodynamic management group and in 12 of 90 patients (13%) in the routine hemodynamic management group (relative risk: 0.33, 95% confidence interval: 0.11 to 0.99, P = 0.036; absolute risk reduction: - 9%, 95% confidence interval: - 17% to - 0.68%, P = 0.034). In this post-hoc secondary analysis, intraoperative personalized goal-directed hemodynamic management reduced the incidence of acute myocardial injury compared to routine hemodynamic management in high-risk patients having major abdominal surgery. This needs to be confirmed in larger prospective trials.