Journal of clinical monitoring and computing
-
J Clin Monit Comput · Dec 2022
Case ReportsRegional respiratory sound abnormalities in pneumothorax and pleural effusion detected via respiratory sound visualization and quantification: case report.
Assessment of respiratory sounds by auscultation with a conventional stethoscope is subjective. We developed a continuous monitoring and visualization system that enables objectively and quantitatively visualizing respiratory sounds. We herein present two cases in which the system showed regional differences in the respiratory sounds. ⋯ Chest X-rays showed a large amount of pleural effusion on the right side. The continuous monitoring and visualization system visually and quantitatively revealed a decreased respiratory volume in the lower right lung field compared with that in the lower left lung field. Our newly developed continuous monitoring and visualization system enabled quantitatively and visually detecting regional differences in respiratory sounds in patients with pneumothorax and pleural effusion.
-
J Clin Monit Comput · Dec 2022
Nociception level index variations in patients with complex regional pain syndrome: a pilot study.
The nociception level index (NOL) is a multi-parameter index that incorporates changes in autonomic parameters to evaluate nociception, with more painful stimuli causing more pronounced index variations. How this nociception monitor relates to the pain experience is uncertain, and patients with chronic pain may respond differently to acute pain due to alterations in pain processing. The goal of this pilot study was to evaluate NOL index variations after a painful physiotherapy exercise in patients with upper limb complex regional pain syndrome. ⋯ The NOL index increased significantly when patients reported increased pain, indicating that it could eventually be useful in the objective assessment of acute pain in the chronic pain patients. However, NOL index was not able to reflect pain levels at rest, before the painful stimulation, in this chronic pain population. Further studies are needed to better assess NOL index utility at rest and to confirm these findings in this specific chronic pain population.
-
J Clin Monit Comput · Dec 2022
Accuracy of calculating mechanical power of ventilation by one commonly used equation.
Gattinoni's equation, [Formula: see text], now commonly used to calculate the mechanical power (MP) of ventilation. However, it calculates only inspiratory MP. In addition, the inclusion of PEEP in Gattinoni's equation raises debate because PEEP does not produce net displacement or contribute to MP. ⋯ When the tidal volume used was 6 ml/Kg, the MP by Gattinoni's equation at PEEP 5 and 10 cmH2O were significantly different (4.51 vs 7.21 J/min, P < 0.001), but the MP by PV loop area was not influenced by PEEPs (6.46 vs 6.47 J/min, P = 0.331). Similar results were observed across all tidal volumes. We conclude that the Gattinoni's equation is not accurate in calculating the MP of a whole ventilatory cycle and is significantly influenced by PEEP, which theoretically does not contribute to MP.
-
J Clin Monit Comput · Dec 2022
Minimizing sevoflurane wastage by sensible use of automated gas control technology in the flow-i workstation: an economic and ecological assessment.
Both ecological and economic considerations dictate minimising wastage of volatile anaesthetics. To reconcile apparent opposing stakes between ecological/economical concerns and stability of anaesthetic delivery, new workstations feature automated software that continually optimizes the FGF to reliably obtain the requested gas mixture with minimal volatile anaesthetic waste. The aim of this study is to analyse the kinetics and consumption pattern of different approaches of sevoflurane delivery with the same 2% end-tidal goal in all patients. ⋯ Further optimization of the AGC algorithms, particularly in the early wash-in period seems feasible. In AGC mode, lower speed settings result in significantly lower consumption of sevoflurane. Routine clinical practice using what historically is called "low flow anaesthesia" (e.g. 2 L/min FGF) should be abandoned, and all anaesthesia machines should be upgraded as soon as possible with automatic delivery technology to minimize atmospheric pollution with volatile anaesthetics.
-
J Clin Monit Comput · Dec 2022
Prediction of sepsis onset in hospital admissions using survival analysis.
To determine the efficacy of modern survival analysis methods for predicting sepsis onset in ICU, emergency, medical/surgical, and TCU departments. We performed a retrospective analysis on ICU, med/surg, ED, and TCU cases from multiple Mercy Health hospitals from August 2018 to March 2020. Patients in these departments were monitored by the Mercy Virtual vSepsis team and sepsis cases were determined and documented in the Mercy EHR via a rule-based engine utilizing clinical data. ⋯ This methodology improves upon previous work by demonstrating excellent model performance when generalizing survival-based prediction methods to both severe sepsis and septic shock as well as non-ICU departments. IRB InformationTrial Registration ID: 1,532,327-1. Trial Effective Date: 12/02/2019.