Journal of clinical monitoring and computing
-
J Clin Monit Comput · Aug 2022
Evaluation of a novel mobile phone application for blood pressure monitoring: a proof of concept study.
To provide information about the clinical relevance of blood pressure (BP) measurement differences between a new smartphone application (OptiBP™) and the reference method (automated oscillometric technique) using a noninvasive brachial cuff in patients admitted to the emergency department. We simultaneously recorded three BP measurements using both the reference method and the novel OptiBP™ (test method), except when the inter-arm difference was > 10 mmHg BP. Each OptiBP™ measurement required 1-min and the subsequent reference method values were compared to the values obtained with OptiBP™ using a Bland-Altman analysis and error grid analysis. ⋯ In this pilot study conducted in stable and awake patients admitted to the emergency department, the absolute agreement between the OptiBP™ and the reference method was moderate. However, when BP measurements were made immediately after an initial calibration, error grid analysis showed that 100% of measurement differences between the OptiBP™ and reference method were categorized as no- or low-risk treatment decisions for all patients. Trial Registration: ClinicalTrials.gov Identifier: NCT04121624.
-
J Clin Monit Comput · Aug 2022
Processed electroencephalography: impact of patient age and surgical position on intraoperative processed electroencephalogram monitoring of burst-suppression.
We previously reported that processed EEG underestimated the amount of burst suppression compared to off-line visual analysis. We performed a follow-up study to evaluate the reasons for the discordance. Forty-five patients were monitored intraoperatively with processed EEG. ⋯ Machine readings for younger patients (age < 65 years) had higher sensitivity (0.96 vs 0.92; p = 0.021) and specificity (0.99 vs 0.88; p = 0.007) for older patients. The duration of burst suppression estimated by the machine generally had good agreement compared with neurologists' estimation using a more precise off-line measurement. Factors that affected the concordance included patient age and position during surgery, but not EEG artifacts.
-
J Clin Monit Comput · Aug 2022
Vigilance: the behavioral impact of quantitative monitoring on administration and antagonism of neuromuscular blocking agents.
The aim of this study was to determine whether use of acceleromyography (1) changes dosing of neuromuscular blocking agents (NMBAs), and (2) increases the time between neostigmine administration and extubation, when compared with subjective assessment of neuromuscular blockade. ⋯ The data presented provides insight about the behavioral engineering inherent to the practice of anesthesiology. Introduction of neuromuscular blockade assessment appeared to increase provider vigilance in dosing of NMBAs-regardless of assessment method. The frequency of intraoperative monitoring (quantitative or subjective) was associated with an increased total dose of NMBA administered and decreased time interval between the last dose of neostigmine and extubation.
-
J Clin Monit Comput · Aug 2022
Observational StudyAssessment of different computing methods of inspiratory transpulmonary pressure in patients with multiple mechanical problems.
While plateau airway pressure alone is an unreliable estimate of lung overdistension inspiratory transpulmonary pressure (PL) is an important parameter to reflect it in patients with ARDS and there is no concensus about which computation method should be used to calculate it. Recent studies suggest that different formulas may lead to different tidal volume and PEEP settings. The aim of this study is to compare 3 different inspiratory PL measurement method; direct measurement (PLD), elastance derived (PLE) and release derived (PLR) methods in patients with multiple mechanical abnormalities. 34 patients were included in this prospective observational study. ⋯ There was a good aggreement and there was no bias between the measurements in Bland-Altman analysis. The estimated bias was similar between the PLD and PLE (- 3.12 ± 11 cmH2O) and PLE and PLR (3.9 ± 10.9 cmH2O) measurements. Our results suggest that standardization of calculation method of inspiratory PL is necessary before using it routinely to estimate alveolar overdistension.