Observational StudyEchocardiographic hemodynamic assessment in decompensated cirrhosis: comparison between Intensivists and Gastroenterologists.
Ascites is a frequent complication of cirrhosis. In intensive care units, initial hemodynamic assessment is frequently performed by echocardiography. This study evaluated the feasibility and usefulness of early hemodynamic assessment in the gastroenterology ward. ⋯ NCT03650660.
-
J Clin Monit Comput · Oct 2023
Zero-heat-flux thermometry over the carotid artery in assessment of core temperature in craniotomy patients.
Zero-heat-flux core temperature measurements on the forehead (ZHF-forehead) show acceptable agreement with invasive core temperature measurements but are not always possible in general anesthesia. However, ZHF measurements over the carotid artery (ZHF-neck) have been shown reliable in cardiac surgery. We investigated these in non-cardiac surgery. ⋯ In percentage index [median (interquartile range)], both ZHF-neck [100 (92-100) %] and ZHF-forehead [100 (92-100) %] scored almost 100% after esophageal nadir. ZHF-neck measures core temperature as reliably as ZHF-forehead in non-cardiac surgery. ZHF-neck is an alternative to ZHF-forehead if the latter cannot be applied.
-
J Clin Monit Comput · Oct 2023
Observational StudyFeasibility analysis of a novel non-invasive ultrasonographic method for the measurement of intra-abdominal pressure in the intensive care unit.
Increased intra-abdominal pressure (IAP) is an important vital sign in critically ill patients and has a negative impact on morbidity and mortality. This study aimed to validate a novel non-invasive ultrasonographic approach to IAP measurement against the gold standard intra-bladder pressure (IBP) method. We conducted a prospective observational study in an adult medical ICU of a university hospital. ⋯ Bland and Altman's analysis showed a bias (0.39 and 0.61 mmHg) and precision (1.38 and 1.51 mmHg) for the comparison of IAPUS1 and IAPUS2 and vs. IBP, respectively with small limits of agreement that were in line with the research guidelines of the Abdominal Compartment Society (WSACS). Our novel ultrasound-based IAP method displayed good correlation and agreement between IAP and IBP at levels up to 15 mmHg and is an excellent solution for quick decision-making in critically ill patients.
-
J Clin Monit Comput · Oct 2023
Clinical TrialBioimpedance based determination of cardiac index does not show enough trueness for point of care use in patients with systolic heart failure.
Cardiac output (CO) is a key parameter in diagnostics and therapy of heart failure (HF). The thermodilution method (TD) as gold standard for CO determination is an invasive procedure with corresponding risks. As an alternative, thoracic bioimpedance (TBI) has gained popularity for CO estimation as it is non-invasive. ⋯ In patients with systolic HF, TBI clearly lacks diagnostic accuracy and cannot be recommended for point-of-care decision making. Depending on the definition of an acceptable PE, TBI may be considered sufficient when systolic HF is absent. Trial registration number: DRKS00018964 (German Clinical Trial Register, retrospectively registered).
-
J Clin Monit Comput · Oct 2023
Observational StudyExhaled patient derived aerosol dispersion during awake tracheal intubation with concurrent high flow nasal therapy.
Awake Tracheal Intubation (ATI) can be performed in cases where there is potential for difficult airway management. It is considered an aerosol generating procedure and is a source of concern to healthcare workers due to the risk of transmission of airborne viral infections, such as SARS-CoV-2. At present, there is a lack of data on the quantities, size distributions and spread of aerosol particles generated during such procedures. ⋯ Patient derived aerosol particles < 5 µm in diameter remained entrained in the exhaled aerosol plume and fell to the floor or onto the subject. Patient derived particles > 5 µm in diameter broke away from the exhaled plume and spread radially throughout the operating room. Irrespective of distance and ventilation status, full airborne protective equipment should be worn by all staff when ATI is being performed on patients with suspected viral respiratory infections.