Journal of clinical monitoring and computing
-
J Clin Monit Comput · Feb 2023
Evaluation of a wrist-worn photoplethysmography monitor for heart rate variability estimation in patients recovering from laparoscopic colon resection.
To evaluate the accuracy of heart rate variability (HRV) parameters obtained with a wrist-worn photoplethysmography (PPG) monitor in patients recovering from minimally invasive colon resection to investigate whether PPG has potential in postoperative patient monitoring. 31 patients were monitored for three days or until discharge or reoperation using a wrist-worn PPG monitor (PulseOn, Finland) with a Holter monitor (Faros 360, Bittium Biosignals, Finland) as a reference measurement device. Beat-to-beat intervals (BBI) and HRV information collected by PPG were compared with RR intervals (RRI) and HRV obtained from the ECG reference after removing artefacts and ectopic beats. The beat-to-beat mean error (ME) and mean absolute error (MAE) of good quality heartbeat intervals obtained by wrist PPG were estimated as - 1.34 ms and 10.4 ms respectively. ⋯ The wrist PPG shows some potential for use in a clinical setting. The accuracy of several HRV parameters analyzed post hoc was found sufficient to be used in further studies concerning postoperative recovery of patients undergoing laparoscopic colon resection, although there were large errors in many common HRV parameters such as RMSSD, pNN50 and NN50, rendering them unusable. ClinicalTrials.gov Identifier: NCT04996511, August 9, 2021, retrospectively registered.
-
J Clin Monit Comput · Feb 2023
Randomized Controlled TrialOutcomes after decrease in hypothermia usage for out of Hospital Cardiac arrest after targeted temperature management study.
Evaluate trends in targeted temperature management with regards to temperature selection, its effect on neurologic outcomes at discharge, and compare this with recent large randomized controlled trial outcomes. ⋯ Out of hospital cardiac arrest patients with persistent comatose state treated with hypothermia of 33 °C had improved odds of discharge with good neurologic outcomes when compared to those treated with targeted normothermia. This improvement of outcomes appears to have been driven by the improved outcomes in the patients who had presented with non-shockable rhythm.
-
J Clin Monit Comput · Feb 2023
Multicenter Study Observational StudyIntra-abdominal hypertension in cardiac surgery patients: a multicenter observational sub-study of the Accuryn registry.
Intra-abdominal hypertension (IAH) is frequently present in the critically ill and is associated with increased morbidity and mortality. Conventionally, intermittent 'spot-check' manual measurements of bladder pressure in those perceived as high risk are used as surrogates for intra-abdominal pressure (IAP). True patterns of IAH remain unknown. ⋯ For maximum consecutive duration of IAH, 84% (115/137) of patients spent at least 12 h in grade I, 62% (85/137) in grade II, 18% (25/137) in grade III, and 2% (3/137) in grade IV IAH. During the first 48 h after cardiac surgery, IAH is common and persistent. Improved and automated monitoring of IAP will increase the detection of IAH-which normally would remain undetected using traditional intermittent monitoring methods.
-
J Clin Monit Comput · Feb 2023
Randomized Controlled TrialPerformance of the bispectral index and electroencephalograph derived parameters of anesthetic depth during emergence from xenon and sevoflurane anesthesia.
Many processed EEG monitors (pEEG) are unreliable when non-GABAergic anesthetic agents are used. The primary aim of the study was to compare the response of the Bispectral Index (BIS) during emergence from anesthesia maintained by xenon and sevoflurane. To better understand the variation in response of pEEG to these agents, we also compared several EEG derived parameters relevant to pEEG monitoring during emergence. Twenty-four participants scheduled for lithotripsy were randomized to receive xenon or sevoflurane anesthesia. ⋯ The spectral edge frequency and composite cortical state parameters increased significantly in both groups during emergence. The BIS index is lower at equivalent stages of behavioural response during emergence from xenon anesthesia when compared to sevoflurane anesthesia, most likely due to differences in how these two agents influence the relative beta ratio. The spectral edge frequency and composite cortical state might better reflect emergence from xenon anaesthesia. Clinical trial number and registry Australia New Zealand Clinical Trials Registry Number: ACTRN12618000916246.