Annals of cardiac anaesthesia
-
Randomized Controlled Trial
Effect of prophylactic amiodarone in patients with rheumatic valve disease undergoing valve replacement surgery.
The study was carried out to evaluate the effect of prophylactic single-dose intravenous amiodarone in patients undergoing valve replacement surgery. Maintenance of sinus rhythm is better than maintenance of fixed ventricular rate in atrial fibrillation (AF) especially in the presence of irritable left or right atrium because of enlargement. Fifty-six patients with valvular heart disease with or without AF were randomly divided into two groups. ⋯ Defibrillation or cardio version was needed in 7.14% patients in group I and 28.57% patients in group II (P=0.078). A single prophylactic intraoperative dose of intravenous amiodarone decreased post bypass arrhythmia in this study in comparison to the control group. Single dose of intraoperative amiodarone may be used to decrease postoperative arrhythmia in open heart surgery.
-
The efficacy of positive end-expiratory pressure (PEEP) in treating intraoperative hypoxemia during one-lung ventilation (OLV) remains in question given conflicting results of prior studies. This study aims to (1) evaluate the efficacy of PEEP during OLV, (2) assess the utility of preoperative predictors of response to PEEP, and (3) explore optimal intraoperative settings that would maximize the effects of PEEP on oxygenation. Forty-one thoracic surgery patients from a single tertiary care university center were prospectively enrolled in this observational study. ⋯ A multivariate analysis did not yield a clinically significant model for predicting PEEP responsiveness. PEEP improved oxygenation in a subset of patients; larger, although still protective tidal volumes favored a positive response to PEEP. No preoperative variables, however, could be identified as reliable predictors for PEEP responders.
-
Renal dysfunction is known to occur during cardiac surgery. A few factors such as perioperative hypotension, use of potential nephrotoxic therapeutic agents, radio opaque contrast media in the recent past, intra-aortic balloon pump (IABP) and cardiopulmonary bypass have been blamed as the contributing factors to the causation of postoperative renal dysfunction in cardiac surgical patients. At times, in patients with renal failure and low cardiac output status, one may face the dilemma if the use of IABP is safe. ⋯ Cystatin C levels significantly decreased from the basal level of 0.98 ± 0.29 to 0.89 ± 0.23 (P value <0.05). Contrary to the belief, Cystatin C, the early indicator of renal dysfunction decreases suggesting absence of renal injury after the use of IABP. Absence of elevation of cystatin C levels in our study suggests the lack of potential of the IABP to cause renal dysfunction in patients who received elective IABP therapy preoperatively.
-
Case Reports
Successful double lumen tube insertion in a patient with unanticipated laryngeal and tracheal web.
A 45-year-old female patient admitted for surgical management of carcinoma esophagus, presented with difficulty in insertion of left-sided 37 F and 35 F double lumen tube (Mallinckrodt® Broncho-Cath). Fiberoptic bronchoscopy revealed a subglottic web in the larynx just below the vocal cords and a tracheal web just above the carina. Differential lung ventilation could be achieved with a 35 F internal diameter double lumen tube (Portex® Blueline® Endobronchial tube).
-
Comparative Study
Comparison of transthoracic electrical bioimpedance cardiac output measurement with thermodilution method in post coronary artery bypass graft patients.
Transthoracic electrical bioimpedance (TEB) has been proposed as a non-invasive, continuous, and cost-effective method of cardiac output (CO) measurement. In this prospective, non-randomized, clinical study, we measured CO with NICOMON (Larsen and Toubro Ltd., Mysore, India) and compared it with thermodilution (TD) method in patients after off-pump coronary artery bypass (OPCAB) graft surgery. We also evaluated the effect of ventilation (mechanical and spontaneous) on the measurement of CO by the two methods. ⋯ The overall percent errors between TD CO and TEB CO were 19.3% (during controlled ventilation) and 17.4% (during spontaneous breathing), respectively. To conclude, a fair correlation was found between TD CO and TEB CO measurements among post-OPCAB patients during controlled ventilation. However, the correlation was weak in spontaneously breathing patients.