J Appl Clin Med Phys
-
J Appl Clin Med Phys · Nov 2015
Comparative StudyPractical dose delivery verification of craniospinal IMRT.
Craniospinal irradiation (CSI) using IMRT allows dose sparing to organs-at-risk (OAR) whilst conforming the dose to the target volume. Due to the complexity of treatment involving several isocenters, the dose distribution created by the inverse-planned segmented fields must be verified prior to treatment. We propose and test methods to verify dose delivery using commonly available dosimetry equipment for commissioning and routine patient-specific dose verification of craniospinal IMRT. ⋯ The median (range) percentage of ArcCHECK diodes with a γ index < 1 for 3%/3 mm criterion is 99.7% (97.1% to 100%). Three different methods of verifying craniospinal IMRT were compared and tested. All techniques offer different benefits and together can be used for 1) commissioning the treatment technique and, separately, for 2) patient-specific pretreatment verification measurements.
-
J Appl Clin Med Phys · Sep 2015
Impact of grid size on uniform scanning and IMPT plans in XiO treatment planning system for brain cancer.
The main purposes of this study are to: 1) evaluate the accuracy of XiO treatment planning system (TPS) for different dose calculation grid size based on head phan-tom measurements in uniform scanning proton therapy (USPT); and 2) compare the dosimetric results for various dose calculation grid sizes based on real computed tomography (CT) dataset of pediatric brain cancer treatment plans generated by USPT and intensity-modulated proton therapy (IMPT) techniques. For phantom study, we have utilized the anthropomorphic head proton phantom provided by Imaging and Radiation Oncology Core (IROC). The imaging, treatment planning, and beam delivery were carried out following the guidelines provided by the IROC. ⋯ However, no distinct trend was obtained between the absolute difference in dosimetric parameter and dose calculation grid size for the OARs. Grid size has a large effect on dose calculation efficiency, and use of 2 mm or less grid size can increase the dose calculation time significantly. It is recommended to use grid size either 2.5 or 3 mm for dose calculations of pediatric brain cancer plans generated by USPT and IMPT techniques in XiO TPS.
-
J Appl Clin Med Phys · Sep 2015
Potential for reduced radiation-induced toxicity using intensity-modulated arc therapy for whole-brain radiotherapy with hippocampal sparing.
The purpose of this study was to retrospectively investigate the accuracy, plan quality, and efficiency of using intensity-modulated arc therapy (IMAT) for whole brain radiotherapy (WBRT) patients with sparing not only the hippocampus (following RTOG 0933 compliance criteria) but also other organs at risk (OARs). A total of 10 patients previously treated with nonconformal opposed laterals whole-brain radiotherapy (NC-WBRT) were retrospectively replanned for hippocampal sparing using IMAT treatment planning. The hippocampus was volumetrically contoured on fused diagnostic T1-weighted MRI with planning CT images and hippocampus avoidance zone (HAZ) was generated using a 5 mm uniform margin around the hippocampus. ⋯ All of these plans were considered clinically acceptable per RTOG 0933 criteria. IMAT planning provided highly conformal and homogenous plan with a fast and effective treatment option for WBRT patients, sparing not only hippocampi but also other OARs, which could potentially result in an additional improvement of the quality life (QoL). In the future, we plan to evaluate the clinical potential of IMAT planning and treatment option with hippocampal and other OARs avoidance in our patient's cohort and asses the QoL of the WBRT patients, as well as simultaneous integrated boost (SIB) for the brain metastases diseases.
-
J Appl Clin Med Phys · May 2015
Flattening filter-free accelerators: a report from the AAPM Therapy Emerging Technology Assessment Work Group.
This report describes the current state of flattening filter-free (FFF) radiotherapy beams implemented on conventional linear accelerators, and is aimed primarily at practicing medical physicists. The Therapy Emerging Technology Assessment Work Group of the American Association of Physicists in Medicine (AAPM) formed a writing group to assess FFF technology. The published literature on FFF technology was reviewed, along with technical specifications provided by vendors. ⋯ Recommendations pertinent to FFF technology, including acceptance testing, commissioning, quality assurance, radiation safety, and facility planning, are presented. Examples of clinical applications are provided. Several of the areas in which future research and development are needed are also indicated.