Modular titanium alloy neck adapter failures in hip replacement--failure mode analysis and influence of implant material.
Modular neck adapters for hip arthroplasty stems allow the surgeon to modify CCD angle, offset and femoral anteversion intraoperatively. Fretting or crevice corrosion may lead to failure of such a modular device due to high loads or surface contamination inside the modular coupling. Unfortunately we have experienced such a failure of implants and now report our clinical experience with the failures in order to advance orthopaedic material research and joint replacement surgery.The failed neck adapters were implanted between August 2004 and November 2006 a total of about 5000 devices. After this period, the titanium neck adapters were replaced by adapters out of cobalt-chromium. Until the end of 2008 in total 1.4% (n = 68) of the implanted titanium alloy neck adapters failed with an average time of 2.0 years (0.7 to 4.0 years) postoperatively. All, but one, patients were male, their average age being 57.4 years (36 to 75 years) and the average weight 102.3 kg (75 to 130 kg). The failures of neck adapters were divided into 66% with small CCD of 130 degrees and 60% with head lengths of L or larger. Assuming an average time to failure of 2.8 years, the cumulative failure rate was calculated with 2.4%. ⋯ Failure of modular titanium alloy neck adapters can be initiated by surface micromotions due to surface contamination or highly loaded implant components. In the present study, the patients at risk were men with an average weight over 100 kg. Modular cobalt chrome neck adapters provide higher safety compared to titanium alloy material.
-
Hand strength is an important independent surrogate parameter to assess outcome and risk of morbidity and mortality. This study aimed to determine the predictive power of cofactors and to predict population-based normative grip and pinch strength. ⋯ The five easy-to-measure cofactors sex, age, body height, categorized occupational demand on the hand, and body weight provide a highly accurate prediction of normative grip and pinch strength.
-
Bmc Musculoskel Dis · Jan 2010
Trigeminal electrophysiology: a 2 x 2 matrix model for differential diagnosis between temporomandibular disorders and orofacial pain.
Pain due to temporomandibular disorders (TMDs) often has the same clinical symptoms and signs as other types of orofacial pain (OP). The possible presence of serious neurological and/or systemic organic pathologies makes differential diagnosis difficult, especially in early disease stages. In the present study, we performed a qualitative and quantitative electrophysiological evaluation of the neuromuscular responses of the trigeminal nervous system. Using the jaw jerk reflex (JJ) and the motor evoked potentials of the trigeminal roots ((b)R-MEPs) tests, we investigated the functional and organic responses of healthy subjects (control group) and patients with TMD symptoms (TMD group). ⋯ In this 2 x 2 matrix diagnostic model, three different types of headache may be identified: 1) those due to organic pathologies directly and indirectly involving the trigeminal nervous system denoted as "Organic Damage"; 2) those in TMD patients; 3) other types of orofacial pain in subjects who could erroneously be considered healthy, denoted as Orofacial Pain "OP". This category of patient should be considered at risk, as organic neurological pathologies could be present and yet not directly affect the trigeminal system, at least in the early stages of the disease.